How to work out what size generator you need

The calculator above does the maths for you. If you'd rather check it yourself, these are the same rules of thumb it uses, with worked examples. Sizes are in kVA, the rating on every generator's plate.

Common generator sizes at a glance

  • Blackout essentials (fridge, lights, phones and a laptop): 2 to 3.5 kVA inverter.
  • Essentials plus a TV, microwave and fans: 3.5 to 5 kVA.
  • Most of the house, including a split system air conditioner: 7 to 10 kVA petrol, or 8 to 12 kVA diesel if it will run often or for long stretches.
  • The whole house, including ducted air conditioning: 10 kVA and up, usually diesel.
  • Camping and 4WD trips (lights, phones and a portable fridge): around 2 kVA inverter.
  • Caravan with air conditioning: 2 to 3.5 kVA inverter.
  • Power tools, chargers and a small compressor: 3.5 to 7 kVA.
  • Welders, large compressors or several tools at once: 7 to 10 kVA petrol for occasional jobs, 8 to 15 kVA diesel for daily use.
  • Shop, office or cool room backup: 10 to 20 kVA diesel.

Browse by size: 1 to 3 kVA, 3 to 8 kVA, 8 to 15 kVA, 15 to 50 kVA, 50 to 150 kVA and 150 kVA and up.

Sizing from amps

Find the amps on the appliance plate, the plug, or the main switch on your switchboard, then:

  • Single phase (240V): divide the amps by 4. A 15 amp load needs about 4 kVA (15 divided by 4 is 3.75, rounded up).
  • Three phase (415V): divide the amps per phase by 1.4. A load of 32 amps per phase needs about 23 kVA.

Working the other way, each kVA gives about 4 amps on single phase and about 1.4 amps per phase on three phase. A 5 kVA generator supplies about 20 amps, and a 20 kVA three phase set about 28 amps per phase.

Sizing from watts or kW

Add up the watts of everything you want running at the same time. The wattage is on the label or plate of each appliance. Divide the total by 1,000 to get kW, then divide by 0.8 (multiply by 1.25) to get the kVA to look for.

For example, a fridge (around 300 W), lights (200 W), a TV (150 W) and a microwave (1,100 W) add up to 1,750 W. That's 1.75 kW, and 1.75 divided by 0.8 is about 2.2, so look at 3 kVA and up.

Fridges, freezers and air conditioners draw extra for a moment when their compressor starts, so leave some room above the bare total.

kVA or kW: what's the difference?

kW is the real power your appliances use. kVA is the total the generator has to supply, including the extra current that motors, compressors and some electronics draw. Larger three phase generators are usually rated at a 0.8 power factor, so a 10 kVA set gives about 8 kW of usable power. That's why we size in kVA and add a margin over your kW.

Motors, pumps and air conditioners

Electric motors draw several times their running current for a moment as they start. That surge, not the running load, is what trips an undersized generator. Pumps, compressors, fridges and air conditioners all have one.

  • Started direct on line (no soft starter or VSD): allow about 3.6 kVA for every kW of motor. A 2.2 kW pump needs about 8 kVA.
  • With a soft starter: allow about 2.5 kVA per kW. The same 2.2 kW pump needs about 5.5 kVA.
  • With a variable speed drive (VSD): allow about 3 kVA per kW. A drive has no start up surge, but its distorted current heats the generator, so Cummins says a drive's load should stay under about half the generator's capacity. The same 2.2 kW pump needs about 7 kVA.

If the motor plate shows horsepower, 1 hp is about 0.75 kW.

Welders

Use the welder's maximum input amps from the nameplate (often marked I1max), not the welding output amps.

  • Modern inverter welders: multiply the input amps by 1.3.
  • Old-style transformer welders: multiply the input amps by 3.

Then convert to kVA: divide by 4 for single phase, or by 1.4 for three phase. A modern welder drawing 15 amps needs about 5 kVA (15 times 1.3 is 19.5 amps, and 19.5 divided by 4 is 4.9, rounded up). Going a size up never hurts a welder.

Standby or prime power?

Standby power is backup that runs during an outage. Prime power means the generator is the main supply for long hours, like an off grid property, a remote worksite or an event. For prime use, add about 30% to the size so the generator isn't working flat out all day.

Single phase or three phase?

Homes, caravans and most small businesses run on single phase (240V). Workshops, farms and commercial sites with three phase motors or a three phase switchboard need a three phase generator (415V). Three phase equipment usually has a round plug with four or five pins. If you're not sure, ask your electrician or give us a call.

Inverter, petrol or diesel?

Inverter generators make clean, stable power that's safe for laptops, phones and modern appliances, and they're quieter and use less fuel at light loads. Conventional open frame generators cost less per kVA and handle worksite knocks and heavy starting loads. Petrol suits occasional and emergency use and costs less to buy. Diesel uses less fuel on long runs, lasts longer and suits standby systems and daily work.

Connecting a generator to your house

Never feed a house by plugging a generator into a power point. Backfeeding is illegal and can electrocute you or line workers. To run your house circuits, a licensed electrician fits a changeover switch and inlet, so the generator and the grid can never connect at the same time. We can arrange the installation.

These are guides, not guarantees. Start up loads, heat, altitude and duty cycle all change the answer. Call us on 07 4728 2796 and we'll confirm the right unit before you buy.

Generator sizing questions

Straight answers to the questions we hear most. Can't see yours? Send the team a message and we'll help you size it.

Contact us
What size generator do I need to run a house?

It depends on what you want running at once. Blackout essentials like the fridge, lights and phones need 2 to 3.5 kVA. Add a TV, microwave and fans and you're at 3.5 to 5 kVA. Most of the house with a split system air conditioner needs 7 to 10 kVA, and the whole house with ducted air conditioning needs 10 kVA or more.

What size generator do I need for a 3 bedroom house?

The number of bedrooms matters less than what you run. Most homes keep the essentials going on 3.5 to 5 kVA, need 7 to 10 kVA to add a split system air conditioner, and 10 kVA or more for ducted air. Add up the appliances you can't do without in the calculator above for a closer answer.

How do I convert amps to kVA?

On single phase (240V), divide the amps by 4. On three phase (415V), divide the amps per phase by 1.4. Round up to the next generator size, so 30 amps on single phase needs about 8 kVA.

How many amps does a generator supply?

Each kVA gives about 4 amps on single phase and about 1.4 amps per phase on three phase. A 5 kVA generator supplies about 20 amps, and a 20 kVA three phase set about 28 amps per phase. If it will run for long hours, plan on about a quarter less.

How do I convert kW to kVA?

Divide the kW by 0.8 (multiply by 1.25) to get the kVA to look for, so 5 kW of load means looking for at least 6.25 kVA. Larger three phase generators are usually rated at a 0.8 power factor, so a 10 kVA set gives about 8 kW of usable power.

What size generator do I need for a welder?

Take the maximum input amps from the welder's nameplate. Multiply by 1.3 for a modern inverter welder or by 3 for an old-style transformer welder, then divide by 4 for single phase (or 1.4 for three phase). A modern welder drawing 15 amps needs about 5 kVA.

What size generator will start a motor or pump?

For a motor started direct on line, allow about 3.6 kVA per kW, so a 2.2 kW pump needs about 8 kVA. With a soft starter, allow about 2.5 kVA per kW, or about 3 kVA per kW with a VSD. The start up surge is what catches out undersized generators.

What size generator do I need for a caravan air conditioner?

A 2 to 3.5 kVA inverter generator suits most caravan air conditioners. The start up surge is the hard part, so go for the bigger end if you also want to charge batteries or boil the kettle while the air conditioner runs.

Should I buy a petrol or diesel generator?

Petrol suits occasional and emergency use and costs less up front. Diesel uses less fuel on long runs, lasts longer and is the better choice for regular use, standby systems and worksites.

Can I plug a generator into my house?

Not through a power point. Backfeeding a house that way is illegal and dangerous. A licensed electrician fits a changeover switch so the generator can safely run your circuits, and we can arrange the installation.

Big job? Get a quote for the whole setup.

Tell us the load, the phase and where it's going. We'll quote the generator, transfer switch, installation and freight, including mine spec builds.

  • Prime and standby diesel sets up to 2,500kVA
  • Automatic transfer switch packages
  • Mine spec upgrades for site requirements
  • Installation and servicing by our electrical team
65kVA Hyundai Diesel Generator DHY65KSE-3
Hyundai DHY series three phase diesel, 65 to 125kVA