{"product_id":"110kva-able-perkins-diesel-generator-pl110pl","title":"110kVA ABLE Perkins Diesel Generator PL110PL","description":"\u003cp\u003eThe PL110PL is a 110kVA three phase diesel generator rated 100kVA (80kW) prime (PRP) and 110kVA (88kW) standby (ESP) at 415V, 50Hz and a power factor of 0.8. A four cylinder, 4.4 litre Perkins diesel, water cooled and running at 1500 rpm, drives a Leroy Somer LSA44.3S5 four-pole brushless alternator with AVR. Electric start is at 12 volts, the battery is included, and an IP67-enclosed RCD and over current protection are fitted.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe ComAp MRS16 controller has a two-wire remote start input, so an external switch or controller can start the set.\u003c\/li\u003e\n\u003cli\u003eTwo 32A and one 20A three phase outlets and one 15A single phase outlet are rated IP66 (dust tight and protected against powerful water jets).\u003c\/li\u003e\n\u003cli\u003eHardwire terminals allow a fixed connection to a site switchboard.\u003c\/li\u003e\n\u003cli\u003eThe canopy has a lock, sound deadening, a weather-resistant powder coat and stainless steel fittings.\u003c\/li\u003e\n\u003cli\u003eFor sites that must contain fuel spills, mine site ready bunding is part of the specification.\u003c\/li\u003e\n\u003cli\u003eAmbient temperatures from -25°C to 45°C are specified, with a coolant heater needed below 5°C, so you can check the set against your site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe tank holds 580 litres and noise is about 66 dB(A) at 7 m. Its design standards are CE, ISO 8528-5:2005, AS 3000-2018 and AS 3010-2017.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eA set this large is chosen for a site's total load rather than for single appliances. Start from a load schedule that lists every motor with its running and starting current and the phase it sits on, and keep the load balanced across the three phases. Pumps, compressors and chillers can draw several times their running current as they start, so the starting sequence matters as much as the total. Check each item's compliance plate, and have an electrician or engineer assess the schedule before the set is specified. Connection to a switchboard should be made by a licensed electrician. Send us your load list and we will help with sizing.\u003c\/p\u003e\n\u003cp\u003eThe PL110PL suits factories, warehouses, cold stores, pumping stations and commercial buildings, as well as mine and construction sites. Its prime and standby ratings let it serve as emergency backup or run regularly on a variable load.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 100kVA (80kW) prime, 110kVA (88kW) standby @ 0.8PF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 140 Amps per phase (prime)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Perkins 1104C-44TAG2 diesel, 1500rpm, water cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Leroy Somer LSA44.3S5 three phase 4-pole brushless alternator with AVR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController:\u003c\/strong\u003e ComAp MRS16 IL4, two-wire remote start\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e 12 volt electric, battery included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Three phase, 415V, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 580 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel use:\u003c\/strong\u003e 22.6 L\/hr at prime load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 25 hrs continuous at prime load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e 66 dB(A) @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x 32 Amp and 1 x 20 Amp three phase and 1 x 15 Amp single phase IP66 outlets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardwire terminals:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e RCD to Australian Standards (IP67 enclosed), over current protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCanopy:\u003c\/strong\u003e Lockable, sound deadened, weather-resistant powder coat, stainless steel fittings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMine spec:\u003c\/strong\u003e Mine site ready bunding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 242 x 113 x 171 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1,874 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3 years or 2,000 hours, prime or standby use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine configuration:\u003c\/strong\u003e 4 cylinder, 4.4 L displacement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection class:\u003c\/strong\u003e IP54\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating conditions:\u003c\/strong\u003e Ambient -25 to 45°C (coolant heater needed below 5°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign standards:\u003c\/strong\u003e CE, ISO 8528-5:2005, AS 3000-2018, AS 3010-2017\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePart of the ABLE Power range at Gen4Sale.\u003c\/p\u003e","brand":"ABLE","offers":[{"title":"Default Title","offer_id":67546752549055,"sku":"PL110PL","price":31458.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/ABLE-PL110PL.jpg?v=1791155531","url":"https:\/\/gen4sale.com.au\/products\/110kva-able-perkins-diesel-generator-pl110pl","provider":"Gen4Sale","version":"1.0","type":"link"}