{"title":"Welling \u0026 Crossley","description":"\u003cp\u003eWelling \u0026amp; Crossley power equipment, built for Australian conditions and backed by national parts support. The range runs from compact petrol generators for the shed and the campsite and quiet inverter models that are safe for sensitive electronics, through battery power stations, to Lister Petter bore pump generators, standby diesel generators and transfer switches. Every unit is delivered Australia-wide. If you are not sure which model suits your job, \u003ca href=\"\/pages\/customer-support\"\u003eask us\u003c\/a\u003e and we will size it for you.\u003c\/p\u003e","products":[{"product_id":"375kva-welling-crossley-petrol-generator-wc-p3750","title":"3.75kVA Welling \u0026 Crossley Petrol Generator WC-P3750","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P3750 is a 3.75kVA (at 0.8 PF) open frame petrol generator producing 3200W maximum and 2800W rated single phase output at 230\/240V, 50Hz. It is powered by the Euro 5 compliant WC-230 single cylinder, 4 stroke OHV air cooled engine with transistor ignition, has electric start as standard, and uses an AVR (automatic voltage regulator) to hold output steady.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric start as standard:\u003c\/strong\u003e push-button starting on a compact open frame unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2800W rated output:\u003c\/strong\u003e sized for tools, lighting and essential appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR regulation:\u003c\/strong\u003e steady voltage for tools and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel economy:\u003c\/strong\u003e 0.6 L\/hr at 1\/4 load from the 15 L tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong run time:\u003c\/strong\u003e a rated 24.6 hours at 1\/4 load on a full tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-C and USB-A charging:\u003c\/strong\u003e devices charge directly from the panel, alongside 2 x 15 Amp outlets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 15 L fuel tank gives a rated 24.6 hours at 1\/4 load, with consumption of 0.6 L\/hr at that load. Noise is rated at 68 dBA at 7 m. Outlets are 2 x IP44 15 Amp, 1 x USB Type C (15W) and 1 x USB Type A (18W).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 2800W rated the WC-P3750 supplies roughly 11.7 A at 240V (approximate). That is typically enough for a fridge, lights, TV and phone charging in a blackout, or a drop saw, drill and work lights on a small job, but not all at full draw at once. A kettle or heater on its own will use most of the capacity. Motors such as compressors and fridges draw a surge at start-up, so start them first. Check appliance plates and add up running watts before connecting.\u003c\/p\u003e\n\u003cp\u003eThe WC-P3750 covers tools and lighting on smaller jobs, camping and caravan appliances, market stalls, farm sheds and light home backup. Home connection must be through an inlet and changeover switch installed by a licensed electrician. For inverter output at a similar size, see the WC-P3200Si.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 3200W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 2800W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ekVA rating:\u003c\/strong\u003e 3.75kVA @ 0.8PF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e WC-230, single cylinder, 4 stroke, OHV, air cooled petrol, Euro 5 compliant, transistor ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 15 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 24.6 hrs @ 1\/4 Load; fuel consumption 0.6 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e 68 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x IP44 15Amp; 1 x USB Type C (15w), 1 x USB Type A (18w)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR:\u003c\/strong\u003e AVR (Automatic Voltage Regulator)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 60 x 58 x 56 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 45 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 Year Limited Welling and Crossley Warranty (battery excluded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191115894975,"sku":"811625","price":1019.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811625_P3750.jpg?v=1789086743"},{"product_id":"875kva-welling-crossley-petrol-generator-wc-p8750","title":"8.75kVA Welling \u0026 Crossley Petrol Generator WC-P8750","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P8750 is an 8.75kVA (at 0.8 PF) open frame petrol generator producing 7000W maximum and 6500W rated single phase output at 230\/240V, 50Hz. It is powered by the Euro 5 compliant WC-420 single cylinder, 4 stroke OHV air cooled engine with transistor ignition, uses an AVR for steady output, and starts by recoil, electronic, 2-wire or wireless remote start.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6500W rated output:\u003c\/strong\u003e capacity for trade tools, workshop gear and home essentials together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless remote start:\u003c\/strong\u003e start the unit from a distance, with electronic and recoil start as alternatives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-wire start:\u003c\/strong\u003e can be wired to a compatible automatic transfer switch to start on mains failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR regulation:\u003c\/strong\u003e automatic voltage regulation for tools and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25 L fuel tank:\u003c\/strong\u003e a rated 16.9 hours at 1\/4 load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP66 outlets plus USB:\u003c\/strong\u003e 2 x 15 Amp IP66 outlets with USB-C and USB-A charging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 25 L fuel tank gives a rated 16.9 hours at 1\/4 load, with fuel consumption of 1.48 L\/hr at that load. Noise is rated at 72 dBA at 7 m. Outlets are 2 x IP66 15 Amp, 1 x USB Type C (15W) and 1 x USB Type A (18W).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 6500W rated the WC-P8750 supplies roughly 27 A at 240V (approximate) in total, with each 15 Amp outlet limited to 15 A. On a trade site that typically covers a drop saw, compressor and lighting together. In a blackout it typically keeps refrigeration, lights, TV, internet and a microwave or kettle going. Motors draw a surge at start-up, so start the largest first and leave headroom. Check appliance plates and add up running watts before connecting.\u003c\/p\u003e\n\u003cp\u003eThe WC-P8750 handles trade site power, workshop duty, farm work, event supply and home backup. Home connection must be through an inlet and changeover switch installed by a licensed electrician. The WC-P8750RCD is the RCD protected variant of this platform.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 7000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 6500W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ekVA rating:\u003c\/strong\u003e 8.75kVA @ 0.8PF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e WC-420, single cylinder, 4 stroke, OHV, air cooled petrol, Euro 5 compliant, transistor ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil \/ Electronic \/ 2-Wire \/ Wireless Remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 25 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 16.9 hrs @ 1\/4 Load; fuel consumption 1.48 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e 72 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x IP66 15Amp; 1 x USB Type C (15w), 1 x USB Type A (18w)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR \/ RCD:\u003c\/strong\u003e AVR; no RCD (a separate WC-P8750-RCD SKU exists but is out of scope)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 70 x 66 x 66 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 90 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 Year Limited Welling and Crossley Warranty (battery excluded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191115927743,"sku":"811626","price":1699.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811626_P8750.jpg?v=1789086744"},{"product_id":"1125kva-welling-crossley-petrol-generator-wc-p11250i","title":"10.8kVA (9000W) Welling \u0026 Crossley Open Frame Petrol Inverter Generator WC-P11250i","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P11250i is an open frame petrol inverter generator rated at 10.8kVA, delivering 9000W maximum and 8500W rated single phase output at 230\/240V, 50Hz. It is driven by the Euro 5 compliant WC-460B single cylinder, 4 stroke OHV engine with DCDI ignition, and it offers four ways to start: recoil, electric, 2-wire and remote. Inverter technology gives clean, stable output, so it suits sensitive electronics as well as tools and appliances.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8500W rated inverter output:\u003c\/strong\u003e big-generator capacity with clean, stable power for electronics and chargers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour start options:\u003c\/strong\u003e recoil as a backup, electric start for everyday use, plus remote start.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-wire start:\u003c\/strong\u003e can be wired to a compatible automatic transfer switch so it starts when mains power fails, or to a float switch to run a pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 Amp IP66 outlet:\u003c\/strong\u003e feeds heavier single loads or a correctly installed generator inlet, alongside a 15 Amp IP44 outlet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-C and USB-A charging:\u003c\/strong\u003e phones and devices charge directly from the panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomy throttling:\u003c\/strong\u003e the inverter throttles the engine back under light loads to save fuel and reduce noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen frame build:\u003c\/strong\u003e an inverter at this output in a straightforward open frame format.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 25 L fuel tank gives a rated 17 hours at 1\/4 load, with fuel consumption of 1.45 L\/hr at that load. Noise is rated at less than 70 dBA at 7 m. Outlets are 1 x IP44 15 Amp, 1 x IP66 32 Amp, 1 x USB Type C (15W) and 1 x USB Type A (18W).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 8500W rated, the WC-P11250i supplies roughly 35 A at 240V (approximate) across its outlets, with no more than 15 A from the 15 Amp outlet. That is typically enough for a fridge and freezer, lights, TV, internet and a microwave or kettle together during a blackout, or several power tools, a compressor and lighting on a work site. Electric motors such as pumps, compressors and air conditioners draw a surge at start-up, so start the largest motor first and leave headroom. Always check the plates on your appliances and add up the running watts before you connect them.\u003c\/p\u003e\n\u003cp\u003eThe WC-P11250i works as well for backup as it does for work. Wired to an automatic transfer switch it takes over through an outage, on the farm it runs pumps and workshop gear, and on site it carries a trade crew's tools. Home connection must be through an inlet and changeover switch installed by a licensed electrician. For an enclosed inverter at the same maximum output, compare the WC-P9000Si.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator type:\u003c\/strong\u003e Open frame inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 9,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 8,500W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e WC-460B, single cylinder, 4 stroke, OHV, air cooled petrol, Euro 5 compliant, DCDI ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil \/ Electric \/ 2-Wire \/ Remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 25 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 17 hrs @ 1\/4 Load; fuel consumption 1.45 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e \u0026lt;70 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 1 x IP44 15Amp, 1 x IP66 32Amp; 1 x USB Type C (15w), 1 x USB Type A (18w)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR \/ RCD:\u003c\/strong\u003e Inverter technology (stable output)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 71.5 x 56 x 68 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 73 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 Year Limited Welling \u0026amp; Crossley Warranty (battery excluded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191115960511,"sku":"811986","price":2419.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811986_WC-P11250i_8.jpg?v=1789086745"},{"product_id":"1375kva-welling-crossley-petrol-generator-wc-p13750","title":"13.75kVA Welling \u0026 Crossley Petrol Generator WC-P13750","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P13750 is a 13.75kVA (at 0.8 PF) open frame petrol generator producing 11000W maximum and 10000W rated single phase output at 230\/240V, 50Hz. Power comes from the Euro 5 compliant WC-690 twin cylinder, 4 stroke OHV air cooled engine with TCI ignition. Output is regulated by an AVR, and the unit starts by recoil, electric, 2-wire or remote start.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10000W rated output:\u003c\/strong\u003e the capacity to run several heavy loads at once on site or through an outage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwin cylinder WC-690 engine:\u003c\/strong\u003e a twin cylinder petrol engine for this output class.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR regulation:\u003c\/strong\u003e automatic voltage regulation for steady output to tools and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric, remote and 2-wire start:\u003c\/strong\u003e 2-wire start allows connection to a compatible automatic transfer switch for start on mains failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 Amp IP66 outlet:\u003c\/strong\u003e for heavier single loads or a correctly installed generator inlet, plus 2 x 15 Amp IP66 outlets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e45 L fuel tank:\u003c\/strong\u003e a large tank for long shifts between refills.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-C and USB-A charging:\u003c\/strong\u003e devices charge directly from the panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt carries a 45 L fuel tank and uses 2.2 L\/hr at 1\/4 load. Noise is rated at less than 90 dBA at 7 m. Outlets are 2 x IP66 15 Amp, 1 x IP66 32 Amp, 1 x USB Type C (15W) and 1 x USB Type A (18W).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 10000W rated the WC-P13750 supplies roughly 42 A at 240V (approximate) in total, with each 15 Amp outlet limited to 15 A. For small commercial backup that is typically enough for refrigeration, lighting, IT, point of sale and some air conditioning together. On a multi-trade site it typically carries several power tools, a compressor and site lighting at once. Large motors draw a surge at start-up, so start the biggest load first and leave headroom. Check appliance plates and add up running watts before connecting.\u003c\/p\u003e\n\u003cp\u003eThe WC-P13750 covers small commercial backup, multi-trade sites, workshops, farm sheds and event power. Home or building connection must be through an inlet and changeover switch installed by a licensed electrician. The WC-P13750RCD is the same platform with factory RCD protection for managed sites.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 11,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 10,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ekVA rating:\u003c\/strong\u003e 13.75kVA @ 0.8PF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e WC-690, twin cylinder, 4 stroke, OHV, air cooled petrol, Euro 5 compliant, TCI ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil \/ Electric \/ 2-Wire \/ Remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 45 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 27 hrs @ 1\/4 Load; fuel consumption 2.2 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e \u0026lt;90 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x IP66 15Amp, 1 x IP66 32Amp; 1 x USB Type C (15w), 1 x USB Type A (18w)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR \/ RCD:\u003c\/strong\u003e AVR; no RCD (separate WC-P13750RCD SKU covers that)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 81 x 64 x 92 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 160 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 Year Limited Welling \u0026amp; Crossley Warranty (battery excluded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191115993279,"sku":"811987","price":3739.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811987.jpg?v=1789086746"},{"product_id":"1375kva-welling-crossley-rcd-petrol-generator-wc-p13750rcd","title":"13.75kVA Welling \u0026 Crossley RCD Petrol Generator WC-P13750RCD","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P13750RCD is a 13.75kVA (at 0.8 PF) open frame petrol generator with factory fitted RCD protection, producing 11000W maximum and 10000W rated single phase output at 230\/240V, 50Hz. It runs on the Euro 5 compliant WC-690 twin cylinder, 4 stroke OHV air cooled engine, with AVR regulation and recoil, electric, 2-wire or remote start.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory fitted RCD:\u003c\/strong\u003e earth leakage protection on the generator itself, for sites that require it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10000W rated output:\u003c\/strong\u003e enough capacity for several heavy loads at once.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR regulation:\u003c\/strong\u003e steady voltage for tools and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwin cylinder WC-690 engine:\u003c\/strong\u003e a twin cylinder petrol engine for this output class.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric, remote and 2-wire start:\u003c\/strong\u003e 2-wire start allows connection to a compatible automatic transfer switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 Amp IP66 outlet:\u003c\/strong\u003e for heavier single loads, plus 2 x 15 Amp IP66 outlets and USB-C and USB-A charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e45 L fuel tank:\u003c\/strong\u003e long running between refills.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt carries a 45 L fuel tank and uses 2.2 L\/hr at 1\/4 load. Noise is rated at less than 90 dBA at 7 m. Outlets are 2 x IP66 15 Amp, 1 x IP66 32 Amp, 1 x USB Type C (15W) and 1 x USB Type A (18W). Note that the RCD protection cannot be used with surge-protected power boards.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 10000W rated the WC-P13750RCD supplies roughly 42 A at 240V (approximate) in total, with each 15 Amp outlet limited to 15 A. On construction and civil sites that typically covers several power tools, a compressor and site lighting together. For commercial standby it typically handles refrigeration, lighting, IT and some air conditioning. Large motors draw a surge at start-up, so start the biggest load first and leave headroom. Check appliance plates and add up running watts before connecting.\u003c\/p\u003e\n\u003cp\u003eThe WC-P13750RCD brings RCD protected high-output power to hire fleets, construction and civil work, councils, events on public land and commercial standby. Building connection must be through an inlet and changeover switch installed by a licensed electrician. The standard WC-P13750 is the same unit without RCD protection.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 11,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 10,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ekVA rating:\u003c\/strong\u003e 13.75kVA @ 0.8PF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e WC-690, twin cylinder, 4 stroke, OHV, air cooled petrol, Euro 5 compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil \/ Electric \/ 2-Wire \/ Remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 45 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 27 hrs @ 1\/4 Load; fuel consumption 2.2 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e \u0026lt;90 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x IP66 15Amp, 1 x IP66 32Amp; 1 x USB Type C (15w), 1 x USB Type A (18w)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC (240V AC), 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR \/ RCD:\u003c\/strong\u003e AVR + RCD fitted; note that RCD protection cannot be used with surge-protected power boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 81 x 64 x 92 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 160 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 Year Limited Welling \u0026amp; Crossley Warranty (battery excluded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116026047,"sku":"811988","price":3789.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811988_WC-P13750RCD.jpg?v=1789086747"},{"product_id":"775kva-welling-crossley-petrol-generator-wc-p7750h","title":"7.75kVA Welling \u0026 Crossley Petrol Generator WC-P7750H","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P7750H is a 7.75kVA (at 0.8 PF) AVR petrol generator producing 6000W maximum and 5500W rated single phase output at 230\/240V, 50Hz. It is powered by a genuine Honda GX390 single cylinder, 4 stroke OHV air cooled engine, Euro 5 compliant, and starts by recoil, push-button electric or 2-wire remote start. A digital display shows volts, frequency and time.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine Honda GX390 engine:\u003c\/strong\u003e backed by a 3 year Honda engine warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR regulation:\u003c\/strong\u003e automatic voltage regulation for tools and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree start options:\u003c\/strong\u003e recoil, push-button electric and 2-wire remote start.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-wire start:\u003c\/strong\u003e can be wired to a compatible automatic transfer switch to start on mains failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital display:\u003c\/strong\u003e shows volts, frequency and time at a glance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP66 outlets plus USB:\u003c\/strong\u003e 2 x 15 Amp IP66 outlets with USB-C and USB-A charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit warranty:\u003c\/strong\u003e engine 3 years (Honda), alternator and frame 2 years (Welling and Crossley); battery excluded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 6.1 L fuel tank and consumption of 1.37 L\/hr at 1\/4 load work out to approximately 4.5 hours at 1\/4 load (calculated, not a published figure). Noise is rated at 89 dBA at 7 m. Outlets are 2 x IP66 15 Amp, 1 x USB Type C (15W) and 1 x USB Type A (18W).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 5500W rated the WC-P7750H supplies roughly 23 A at 240V (approximate) in total, with each 15 Amp outlet limited to 15 A. On site it typically runs a drop saw, a compressor and work lights together. In a blackout it typically covers refrigeration, lights, TV, internet and a microwave or kettle. Motors draw a surge at start-up, so start the largest first and leave headroom. Check appliance plates and add up running watts before connecting.\u003c\/p\u003e\n\u003cp\u003eThe WC-P7750H covers site power, home backup, farm work, events and touring duty, with AVR-regulated output for tools and appliances plus USB-A and USB-C charging. Home connection must be through an inlet and changeover switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 6000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 5500W (data sheet: '5500W Max. 15A')\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ekVA rating:\u003c\/strong\u003e 7.75kVA @ 0.8PF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Genuine Honda GX390, single cylinder, 4 stroke, OHV, air cooled petrol, Euro 5 compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil, Push-button electric, 2 wire remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 6.1 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel consumption:\u003c\/strong\u003e 1.37 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e 89 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x IP66 15Amp; 1 x USB Type C (15w), 1 x USB Type A (18w)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR \/ RCD:\u003c\/strong\u003e AVR; no RCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 55 x 70 x 66 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 80 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Split warranty: Engine 3 years (Honda), Alternator \u0026amp; Frame 2 years (Welling and Crossley); battery excluded\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116058815,"sku":"811992","price":3879.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811992.jpg?v=1789086748"},{"product_id":"38kva-3200w-welling-crossley-petrol-inverter-generator-wc-p3200si","title":"3.8kVA (3200W) Welling \u0026 Crossley Petrol Inverter Generator WC-P3200Si","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P3200Si is an enclosed petrol inverter generator producing 3200W maximum and 3000W rated pure sine wave output at 230\/240V, 50Hz, single phase. It runs on the Euro 5 compliant WC-150B 4 stroke OHV air cooled engine with recoil start.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure sine wave inverter output:\u003c\/strong\u003e suits laptops, TVs, chargers and modern caravan electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3000W rated output:\u003c\/strong\u003e runs a useful mix of appliances at camp or through a blackout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured noise rating:\u003c\/strong\u003e 64 dBA at 7 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecoil start:\u003c\/strong\u003e simple starting with no battery to maintain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosed, compact frame:\u003c\/strong\u003e 50 x 31 x 45 cm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel economy:\u003c\/strong\u003e 0.45 L\/hr at 1\/4 load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-C and USB-A charging:\u003c\/strong\u003e devices charge directly, alongside 2 x 15 Amp outlets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe WC-P3200Si carries a 6 L fuel tank and uses 0.45 L\/hr at 1\/4 load. Noise is rated at 64 dBA at 7 m. Outlets are 2 x IP44 15 Amp, 1 x USB Type C (15W) and 1 x USB Type A (18W).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 3000W rated the WC-P3200Si supplies roughly 12.5 A at 240V (approximate). At camp that typically covers a fridge, lights, a TV, device charging and a coffee machine or kettle used on its own. In a blackout it typically keeps the fridge, freezer, lights and internet going. Motor loads such as fridges and pumps draw a surge at start-up, so start them first. Check appliance plates and add up running watts before connecting. For caravan air conditioning, the WC-P6000Si nearly doubles the output.\u003c\/p\u003e\n\u003cp\u003eThe WC-P3200Si runs the sensitive gear that conventional generators are less suited to: laptops, TVs and modern caravan electronics, at campsites, on the road, at market stalls and through blackouts at home. Home connection must be through an inlet and changeover switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 3,200W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 3,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e WC-150B, Euro 5 compliant, 4 stroke, OHV, air cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 6 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 7.5 hrs @ 1\/4 Load; fuel consumption 0.45 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e 64 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x IP44 15Amp; 1 x USB Type C (15w), 1 x USB Type A (18w)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 50 x 31 x 45 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 23 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 Year Limited Welling \u0026amp; Crossley Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116091583,"sku":"811989","price":1119.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811989_WC-P3200Si.jpg?v=1789086749"},{"product_id":"72kva-6000w-welling-crossley-petrol-inverter-generator-wc-p6000si","title":"7.2kVA (6000W) Welling \u0026 Crossley Petrol Inverter Generator WC-P6000Si","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P6000Si is an enclosed petrol inverter generator rated at 7.2kVA, producing 6000W maximum and 5500W rated pure sine wave output at 230\/240V, 50Hz, single phase. It is powered by the Euro 5 compliant WC-320B 4 stroke OHV air cooled engine and starts by recoil, electronic, 2-wire or wireless remote start.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5500W rated pure sine wave output:\u003c\/strong\u003e clean power with capacity for heavier appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless remote start:\u003c\/strong\u003e start the unit without walking to it, with electronic and recoil start as alternatives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-wire start:\u003c\/strong\u003e can be wired to a compatible automatic transfer switch to start on mains failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 Amp IP66 outlet:\u003c\/strong\u003e for heavier single loads or a correctly installed generator inlet, plus a 15 Amp IP44 outlet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosed design:\u003c\/strong\u003e noise rated at 64 dBA at 7 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-C and USB-A charging:\u003c\/strong\u003e devices charge directly from the panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe WC-P6000Si carries a 13.5 L fuel tank and uses 1.35 L\/hr at 1\/4 load. Noise is rated at 64 dBA at 7 m. Outlets are 1 x IP44 15 Amp, 1 x IP66 32 Amp, 1 x USB Type C (15W) and 1 x USB Type A (18W).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 5500W rated the WC-P6000Si supplies roughly 23 A at 240V (approximate), with the 15 Amp outlet limited to 15 A. It is the caravan air conditioner size: typically enough to start and run a rooftop air conditioner with capacity spare for the fridge and chargers. In a blackout it typically covers refrigeration, lights, TV, internet and a microwave or kettle. Air conditioners and other motors draw a surge at start-up, so start them first. Check appliance plates and add up running watts before connecting.\u003c\/p\u003e\n\u003cp\u003eThe WC-P6000Si serves caravan and touring setups, home backup, food vans and mobile business duty, with inverter output for sensitive electronics. Home connection must be through an inlet and changeover switch installed by a licensed electrician. The WC-P9000Si steps the format up to 9000W.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 6,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 5,500W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e WC-320B, Euro 5 compliant, 4 stroke, OHV, air cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil \/ Electronic \/ 2-Wire \/ Wireless Remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 13.5 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 15 hrs @ 1\/4 Load; fuel consumption 1.35 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e 64 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 1 x IP44 15Amp, 1 x IP66 32Amp; 1 x USB Type C (15w), 1 x USB Type A (18w)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 64 x 48 x 55 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 57.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 Year Limited Welling \u0026amp; Crossley Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116124351,"sku":"811990","price":1939.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811990_WC-P6000Si_3.jpg?v=1789086752"},{"product_id":"108kva-9000w-welling-crossley-petrol-inverter-generator-wc-p9000si","title":"10.8kVA (9000W) Welling \u0026 Crossley Petrol Inverter Generator WC-P9000Si","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P9000Si is an enclosed petrol inverter generator rated at 10.8kVA, producing 9000W maximum and 8200W rated pure sine wave output at 230\/240V, 50Hz, single phase. It runs on the Euro 5 compliant WC-460B 4 stroke OHV air cooled engine and starts by recoil, electric, 2-wire or remote start.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8200W rated pure sine wave output:\u003c\/strong\u003e inverter quality power at a capacity suited to home backup and work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosed inverter design:\u003c\/strong\u003e rated at 64 dBA at 7 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric and remote start:\u003c\/strong\u003e start at the panel or remotely, with recoil as a backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-wire start:\u003c\/strong\u003e can be wired to a compatible automatic transfer switch to start when mains power fails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree IP66 power outlets:\u003c\/strong\u003e 2 x 15 Amp plus 1 x 32 Amp for heavier single loads or a correctly installed generator inlet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-C and USB-A ports:\u003c\/strong\u003e device charging straight from the panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e27 L fuel tank:\u003c\/strong\u003e a rated 18 hours at 1\/4 load between refills.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuel consumption is 1.45 L\/hr at 1\/4 load from the 27 L tank, for a rated run time of 18 hours at that load. Noise is rated at 64 dBA at 7 m. Outlets are 2 x IP66 15 Amp, 1 x IP66 32 Amp, 1 x USB Type C (15W) and 1 x USB Type A (18W).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 8200W rated the WC-P9000Si delivers roughly 34 A at 240V (approximate) in total, with each 15 Amp outlet limited to 15 A. In a blackout that is typically enough for refrigeration, lights, TV and internet, a microwave or kettle and some air conditioning together. On a job or in a food van it typically covers cooking equipment, coffee machines and power tools within that total. Motors draw a surge at start-up, so start the largest load first and keep a margin. Check appliance plates and add up running watts before connecting.\u003c\/p\u003e\n\u003cp\u003eThe WC-P9000Si takes inverter power beyond touring into home backup, food vans, mobile businesses and work duty, running sensitive equipment that needs both quantity and quality of power. Home connection must be through an inlet and changeover switch installed by a licensed electrician. For an open frame inverter at the same maximum output, compare the WC-P11250i.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 9,000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 8,200W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e WC-460B, Euro 5 compliant, 4 stroke, OHV, air cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil \/ Electric \/ 2-Wire \/ Remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 27 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 18 hrs @ 1\/4 Load; fuel consumption 1.45 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e 64 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x IP66 15Amp, 1 x IP66 32Amp; 1 x USB Type C (15w), 1 x USB Type A (18w)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 67 x 73.5 x 75.5 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 99 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 Year Limited Welling \u0026amp; Crossley Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116189887,"sku":"811991","price":3789.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811991_WC-P9000Si.jpg?v=1789086752"},{"product_id":"600w-welling-crossley-portable-power-station-wc-bg600","title":"600W Welling \u0026 Crossley Portable Power Station WC-BG600","description":"\u003cp\u003eThe WC-BG600 is a battery power station from Welling \u0026amp; Crossley, rated at 600W continuous with 1200W maximum (surge) output from a 512Wh LiFePO4 battery. It has no engine, fuel or exhaust: 240 V AC comes from a built-in inverter, alongside USB, 12 V DC and wireless charging outputs, and the battery recharges from a wall socket or from solar panels through the built-in MPPT controller.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e512Wh LiFePO4 battery:\u003c\/strong\u003e lithium iron phosphate cells sized for a camp fridge, lighting and device charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e600W rated, 1200W surge:\u003c\/strong\u003e enough headroom for the start-up draw of small appliances and chargers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure battery operation:\u003c\/strong\u003e no engine, fuel or exhaust, so it can be used inside a home, tent or vehicle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo 240 V AC outlets:\u003c\/strong\u003e 15 A pattern sockets for standard household plugs within the 600W rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-C 100W:\u003c\/strong\u003e fast charging for laptops, tablets and USB-C camera gear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 V outputs:\u003c\/strong\u003e a car charger socket and two DC5521 outlets at 10 A for 12 V fridges, lights and accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar input with MPPT:\u003c\/strong\u003e 18 to 25 V DC at up to 200W, so panels can top it up away from mains power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFrom a wall socket it recharges to 80% in about 2 hours (200W AC input). Run time is load dependent: as listed for this model, a 45W camp fridge runs for roughly 10 hours, a 100W load for about 4 hours. Outputs: 2 x AC 240V\/50Hz\/15A (600W, surge 1200W); 2 x USB-A 24W; 1 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 1 x Wireless charging up to 15W. Inputs: AC Input 230V 50Hz 200W max; Solar Input 18-25V DC 200W max (MPPT, 10A max).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eWith 600W continuous it typically suits phones, laptops, camera batteries, LED lighting, a 12 V or small 240 V fridge, a TV or modem and router through a blackout. It is not suited to heaters, kettles, hair dryers or power tools above 600W. Run time falls as load rises, so divide the battery capacity by the total watts you plan to draw for a rough estimate, and allow for inverter losses. Check the rating plate on each appliance, and remember that motor loads such as fridges, pumps and compressors draw a start-up surge well above their running watts.\u003c\/p\u003e\n\u003cp\u003eThe WC-BG600 suits camping and touring, weekend getaways, home blackout kits for communications and lighting, photographers and content creators on location, and markets or stalls that need lighting and a card terminal. Charged from the wall before you leave or from solar on site, it covers the small loads a generator is overkill for. The WC-BG1200 doubles the output for bigger appliances.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 600W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 1200W (surge)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 512Wh LiFePO4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e load dependent; a 45W camp fridge runs for roughly 10 hours, a 100W load for about 4 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge time (AC, to 80%):\u003c\/strong\u003e approx. 2 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x AC 240V\/50Hz\/15A (600W, surge 1200W); 2 x USB-A 24W; 1 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 1 x Wireless charging up to 15W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e AC Input 230V 50Hz 200W max; Solar Input 18-25V DC 200W max (MPPT, 10A max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 22.8 x 16.5 x 17 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116222655,"sku":"811993","price":909.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811993.jpg?v=1789086752"},{"product_id":"1200w-welling-crossley-portable-power-station-wc-bg1200","title":"1200W Welling \u0026 Crossley Portable Power Station WC-BG1200","description":"\u003cp\u003eThe WC-BG1200 is a battery power station from Welling \u0026amp; Crossley, rated at 1200W continuous with 2400W maximum (surge) output from a 1,152Wh LiFePO4 battery. It has no engine, fuel or exhaust: 240 V AC comes from a built-in inverter, alongside USB, 12 V DC and wireless charging outputs, and the battery recharges from a wall socket or from solar panels through the built-in MPPT controller.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1,152Wh LiFePO4 battery:\u003c\/strong\u003e lithium iron phosphate cells with enough capacity for a camp fridge through most of a day and night.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1200W rated, 2400W surge:\u003c\/strong\u003e headroom for the start-up draw of fridges and small motor loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast AC charging:\u003c\/strong\u003e 700W AC input takes it to 80% in approximately 70 minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure battery operation:\u003c\/strong\u003e no engine, fuel or exhaust, so it can be used indoors during an outage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree 240 V AC outlets:\u003c\/strong\u003e 15 A pattern sockets for standard household plugs within the 1200W rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo USB-C 100W ports:\u003c\/strong\u003e charge two laptops alongside phones on the four USB-A ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar input with MPPT:\u003c\/strong\u003e 18 to 25 V DC at up to 400W (20 A max) for off-grid top-ups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFrom a wall socket it recharges to 80% in approximately 70 minutes (700W AC input). Run time is load dependent: as listed for this model, a 45W camp fridge runs for close to a day, a 100W load for about 10 hours. Outputs: 3 x AC 240V\/50Hz\/15A (1200W, surge 2400W); 4 x USB-A 24W; 2 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 1 x Wireless charging up to 15W. Inputs: AC Input 230V 50Hz 700W max; Solar Input 18-25V DC 400W max (MPPT, 20A max).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eWith 1200W continuous it typically handles a household fridge, a TV and entertainment gear, a modem and router, lighting, laptops, a small microwave or a single power tool of up to 1200W, one higher draw item at a time. Kettles, heaters and hair dryers above 1200W are beyond it. Run time falls as load rises, so divide the battery capacity by the total watts you plan to draw for a rough estimate, and allow for inverter losses. Check the rating plate on each appliance, and remember that motor loads such as fridges, pumps and compressors draw a start-up surge well above their running watts.\u003c\/p\u003e\n\u003cp\u003eThe WC-BG1200 suits home blackout backup for refrigeration and communications, camping and caravan touring, tradies needing a charge station for batteries and laptops, and stallholders and mobile businesses. It is a step up from the WC-BG600 for bigger appliances, and the WC-BG2000 steps up again for sustained appliance loads.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 1200W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 2400W (surge)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 1,152Wh LiFePO4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e load dependent; a 45W camp fridge runs for close to a day, a 100W load for about 10 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge time (AC, to 80%):\u003c\/strong\u003e approx. 70 min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 3 x AC 240V\/50Hz\/15A (1200W, surge 2400W); 4 x USB-A 24W; 2 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 1 x Wireless charging up to 15W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e AC Input 230V 50Hz 700W max; Solar Input 18-25V DC 400W max (MPPT, 20A max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 34.8 x 24.5 x 22.6 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 14 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116255423,"sku":"811994","price":1199.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811994.jpg?v=1789086753"},{"product_id":"2000w-welling-crossley-portable-power-station-wc-bg2000","title":"2000W Welling \u0026 Crossley Portable Power Station WC-BG2000","description":"\u003cp\u003eThe WC-BG2000 is a battery power station from Welling \u0026amp; Crossley, rated at 2000W continuous with 4000W maximum (surge) output from a 1,843Wh LiFePO4 battery. It has no engine, fuel or exhaust: 240 V AC comes from a built-in inverter, alongside USB, 12 V DC and wireless charging outputs, and the battery recharges from a wall socket or from solar panels through the built-in MPPT controller.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1,843Wh LiFePO4 battery:\u003c\/strong\u003e lithium iron phosphate cells with the capacity to keep a camp fridge going for about a day and a half.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2000W rated, 4000W surge:\u003c\/strong\u003e runs most single household appliances, with surge headroom for motor start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1200W AC charging:\u003c\/strong\u003e recharges to 80% from a wall socket in approximately 70 minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide-range solar input:\u003c\/strong\u003e 10 to 150 V DC at up to 1200W through the MPPT controller, suiting a range of panel arrays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure battery operation:\u003c\/strong\u003e no engine, fuel or exhaust, so it can be used indoors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree 240 V AC outlets:\u003c\/strong\u003e 15 A pattern sockets within the 2000W rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo wireless charging pads:\u003c\/strong\u003e plus USB-A, USB-C 100W and 12 V outputs for devices and accessories.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFrom a wall socket it recharges to 80% in approximately 70 minutes (1200W AC input). Run time is load dependent: as listed for this model, a 45W camp fridge runs for about a day and a half, a 100W load for around 15 hours. Outputs: 3 x AC 240V\/50Hz\/15A (2000W, surge 4000W); 2 x USB-A 24W; 1 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 2 x Wireless charging up to 15W. Inputs: AC Input 230V 50Hz 1200W max; Solar Input 10-150V DC 1200W max (MPPT).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eWith 2000W continuous it typically handles most household appliances one at a time: a fridge or freezer, microwave, kettle or toaster of up to 2000W, TV, lighting, laptops and a modem and router, or a circular saw or drill on a job site. Run time falls as load rises, so divide the battery capacity by the total watts you plan to draw for a rough estimate, and allow for inverter losses. Check the rating plate on each appliance, and remember that motor loads such as fridges, pumps and compressors draw a start-up surge well above their running watts.\u003c\/p\u003e\n\u003cp\u003eThe WC-BG2000 suits home backup through outages for refrigeration, communications and lighting, extended camping and touring with solar top-ups, small worksites and trades, and off-grid cabins with a modest solar array. The WC-BG3600 and WC-BG5500 extend the format to worksite loads.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 2000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 4000W (surge)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 1,843Wh LiFePO4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e load dependent; a 45W camp fridge runs for about a day and a half, a 100W load for around 15 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge time (AC, to 80%):\u003c\/strong\u003e approx. 70 min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 3 x AC 240V\/50Hz\/15A (2000W, surge 4000W); 2 x USB-A 24W; 1 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 2 x Wireless charging up to 15W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e AC Input 230V 50Hz 1200W max; Solar Input 10-150V DC 1200W max (MPPT)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 53.6 x 36.1 x 33.8 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 30 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116288191,"sku":"811995","price":2229.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811995.jpg?v=1789086754"},{"product_id":"3600w-welling-crossley-portable-power-station-wc-bg3600","title":"3600W Welling \u0026 Crossley Portable Power Station WC-BG3600","description":"\u003cp\u003eThe WC-BG3600 is a battery power station from Welling \u0026amp; Crossley, rated at 3600W continuous with 7200W maximum (surge) output from a 3,840Wh LiFePO4 battery. It has no engine, fuel or exhaust: 240 V AC comes from a built-in inverter, alongside USB, 12 V DC and wireless charging outputs, and the battery recharges from a wall socket or from solar panels through the built-in MPPT controller.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3,840Wh LiFePO4 battery:\u003c\/strong\u003e lithium iron phosphate cells with generator-class capacity, enough for a camp fridge for about three days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3600W rated, 7200W surge:\u003c\/strong\u003e runs higher draw appliances and tools, with headroom for motor start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2200W AC charging:\u003c\/strong\u003e recharges to 80% from a wall socket in approximately 100 minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2400W solar input:\u003c\/strong\u003e 10 to 150 V DC through the MPPT controller, for substantial off-grid charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour 240 V AC outlets:\u003c\/strong\u003e 15 A pattern sockets within the 3600W rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 V 30 A output:\u003c\/strong\u003e a high current 12 V DC outlet (360W max) for 12 V fridges, pumps and accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure battery operation:\u003c\/strong\u003e no engine, fuel or exhaust, so it can be used indoors and on noise-restricted sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFrom a wall socket it recharges to 80% in approximately 100 minutes (2200W AC input). Run time is load dependent: as listed for this model, a 45W camp fridge runs for about three days, a 100W load for over 30 hours. Outputs: 4 x AC 240V\/50Hz\/15A (3600W, surge 7200W); 4 x USB-A 25W; 2 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 1 x DC 12V\/30A 360W max; 1 x Wireless charging up to 15W. Inputs: AC Input 230V 50Hz 2200W max; Solar Input 10-150V DC 2400W max (MPPT).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eWith 3600W continuous it typically handles a fridge and freezer together with lighting and electronics, or higher draw items such as a kettle, microwave, induction cooktop element, drop saw or compressor within the rating. Run time falls as load rises, so divide the battery capacity by the total watts you plan to draw for a rough estimate, and allow for inverter losses. Check the rating plate on each appliance, and remember that motor loads such as fridges, pumps and compressors draw a start-up surge well above their running watts.\u003c\/p\u003e\n\u003cp\u003eThe WC-BG3600 suits home backup, noise-restricted worksites and indoor fit-outs, events, film sets and catering, and off-grid cabins with a solar array, recharged overnight or from solar between uses. The WC-BG5500 is the flagship at 5500W.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 3600W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 7200W (surge)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 3,840Wh LiFePO4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e load dependent; a 45W camp fridge runs for about three days, a 100W load for over 30 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge time (AC, to 80%):\u003c\/strong\u003e approx. 100 min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 4 x AC 240V\/50Hz\/15A (3600W, surge 7200W); 4 x USB-A 25W; 2 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 1 x DC 12V\/30A 360W max; 1 x Wireless charging up to 15W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e AC Input 230V 50Hz 2200W max; Solar Input 10-150V DC 2400W max (MPPT)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 50.2 x 50.8 x 29.2 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 51 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116320959,"sku":"811996","price":4668.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811996.jpg?v=1789086756"},{"product_id":"5500w-welling-crossley-portable-power-station-wc-bg5500","title":"5500W Welling \u0026 Crossley Portable Power Station WC-BG5500","description":"\u003cp\u003eThe WC-BG5500 is a battery power station from Welling \u0026amp; Crossley, rated at 5500W continuous with 11000W maximum (surge) output from a 5,376Wh LiFePO4 battery. It has no engine, fuel or exhaust: 240 V AC comes from a built-in inverter, alongside USB, 12 V DC and wireless charging outputs, and the battery recharges from a wall socket or from solar panels through the built-in MPPT controller.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5,376Wh LiFePO4 battery:\u003c\/strong\u003e the flagship of the WC-BG range, with enough capacity for a camp fridge for around four days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5500W rated, 11000W maximum:\u003c\/strong\u003e runs several appliances together, with headroom for motor start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix 240 V AC outlets:\u003c\/strong\u003e up to 3600W from any one outlet and 5500W in total.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2200W AC charging:\u003c\/strong\u003e recharges to 80% from a wall socket in approximately 130 minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2400W solar input:\u003c\/strong\u003e 10 to 150 V DC through the MPPT controller, ready to anchor an off-grid system as panels are added.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 V 30 A output:\u003c\/strong\u003e a high current 12 V DC outlet (360W max) alongside car charger, DC5521, USB and wireless outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure battery operation:\u003c\/strong\u003e no engine, fuel or exhaust, so it can be used indoors and on noise-restricted sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFrom a wall socket it recharges to 80% in approximately 130 minutes (2200W AC input). Run time is load dependent: as listed for this model, a 45W camp fridge runs for around four days, a 100W load for over 45 hours. Outputs: 6 x AC 240V\/50Hz\/15A (3600W per outlet, 5500W total); 4 x USB-A 25W; 2 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 1 x DC 12V\/30A 360W max; 1 x Wireless charging up to 15W. Inputs: AC Input 230V 50Hz 2200W max; Solar Input 10-150V DC 2400W max (MPPT).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eWith 5500W continuous it typically handles a home's essential loads together, such as refrigeration, lighting, electronics and a microwave or kettle, or a combination of power tools on site, within the 5500W total and 3600W per outlet limits. Run time falls as load rises, so divide the battery capacity by the total watts you plan to draw for a rough estimate, and allow for inverter losses. Check the rating plate on each appliance, and remember that motor loads such as fridges, pumps and compressors draw a start-up surge well above their running watts.\u003c\/p\u003e\n\u003cp\u003eThe WC-BG5500 suits home backup for essentials, event and film power, worksites where engines are not an option, and off-grid cabins or sheds with solar. For engine-driven power at similar output, compare the WC-P6000Si inverter generator.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 5500W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 11000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery capacity:\u003c\/strong\u003e 5,376Wh LiFePO4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e load dependent; a 45W camp fridge runs for around four days, a 100W load for over 45 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge time (AC, to 80%):\u003c\/strong\u003e approx. 130 min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 6 x AC 240V\/50Hz\/15A (3600W per outlet, 5500W total); 4 x USB-A 25W; 2 x USB-C 100W; 1 x Car Charger 12V\/10A; 2 x DC5521 12V\/10A; 1 x DC 12V\/30A 360W max; 1 x Wireless charging up to 15W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e AC Input 230V 50Hz 2200W max; Solar Input 10-150V DC 2400W max (MPPT)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 60.2 x 60.2 x 34 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 70 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":46191116353727,"sku":"811997","price":5609.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/811997.jpg?v=1789086757"},{"product_id":"875kva-welling-crossley-rcd-petrol-generator-wc-p8750rcd","title":"8.75kVA Welling \u0026 Crossley RCD Petrol Generator WC-P8750RCD","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P8750RCD is an 8.75kVA (at 0.8 PF) open frame petrol generator with RCD protected outlets, producing 7000W maximum and 6500W rated single phase output at 230\/240V, 50Hz. It runs on the Euro 5 compliant WC-420 420cc, 4 stroke OHV air cooled engine with transistor ignition, has AVR regulation, and starts by recoil, electric, 2-wire or wireless remote start.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCD fitted:\u003c\/strong\u003e earth leakage protection on the generator itself, for sites that require it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6500W rated output:\u003c\/strong\u003e capacity for several tools and lights at once.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR regulation:\u003c\/strong\u003e automatic voltage regulation for tools and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour start options:\u003c\/strong\u003e recoil, electric, 2-wire and wireless remote.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-wire start:\u003c\/strong\u003e can be wired to a compatible automatic start system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25 L fuel tank:\u003c\/strong\u003e a rated 16.9 hours at 1\/4 load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 25 L fuel tank gives a rated 16.9 hours at 1\/4 load, with fuel consumption of 1.48 L\/hr at that load. Noise is rated at 72 dBA at 7 m. Output is through 2 x IP66 15 Amp RCD protected outlets. Note that it is not for use with equipment that has built-in RCD protection.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 6500W rated the WC-P8750RCD supplies roughly 27 A at 240V (approximate) in total, with each 15 Amp outlet limited to 15 A. On construction and civil sites that typically covers a drop saw, compressor and lighting together. At events and market stalls it typically runs cooking equipment, fridges and lighting within that total. Motors draw a surge at start-up, so start the largest first and leave headroom. Check appliance plates and add up running watts before connecting.\u003c\/p\u003e\n\u003cp\u003eThe WC-P8750RCD is built for sites that need earth leakage protection on the generator: construction and civil work, hire fleets, councils and schools, farms, and events or market stalls. The standard WC-P8750 is the same platform without the RCD.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum output:\u003c\/strong\u003e 7000W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output:\u003c\/strong\u003e 6500W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ekVA rating:\u003c\/strong\u003e 8.75kVA @ 0.8PF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e WC-420, 420cc, 4 stroke, OHV, air cooled petrol, Euro 5 compliant, transistor ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil \/ Electric \/ 2-Wire \/ Wireless Remote\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Petrol - 91 octane unleaded\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 25 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun time:\u003c\/strong\u003e 16.9 hrs @ 1\/4 Load; fuel consumption 1.48 L\/Hr @ 1\/4 Load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise level:\u003c\/strong\u003e 72 dBA @ 7m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x IP66 15 Amp, RCD protected\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase \/ voltage:\u003c\/strong\u003e Single phase, 230\/240V AC, 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAVR \/ RCD:\u003c\/strong\u003e AVR + RCD fitted; not for use with equipment that has built-in RCD protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 70 x 66 x 66 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 90 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 Year Limited Welling \u0026amp; Crossley Warranty (battery excluded)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67511469670591,"sku":"813072","price":1949.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/813072.jpg?v=1790502060"},{"product_id":"welling-crossley-63a-single-phase-manual-transfer-switch","title":"Welling \u0026 Crossley 63A Single Phase Manual Transfer Switch","description":"\u003cp\u003eA 63 amp single phase manual transfer switch (changeover switch) from Welling \u0026amp; Crossley, for switching a site between mains and generator supply by hand.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e63 A rating:\u003c\/strong\u003e suits single phase generator installations up to the switch rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual changeover:\u003c\/strong\u003e the operator moves the site from mains to generator and back, with no automatic controls to configure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase:\u003c\/strong\u003e for single phase switchboards and generators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA changeover switch is the safe way to run a site from a generator: it isolates the mains before the generator supply is connected, so generator power cannot feed back into the grid. Never connect a generator to house wiring or a power point any other way. The switch connects into your switchboard, so installation is a job for a licensed electrician. Send us the generator model and we will confirm the right switch before you order.\u003c\/p\u003e\n\u003cp\u003eIt suits homes, farms, workshops and small businesses with a single phase standby or portable generator, where someone is on hand to switch over during an outage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your generator and switchboard details and the team will come back to you quickly.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 80-SWITCH-CHANGEOVER-63A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRating:\u003c\/strong\u003e 63A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Manual changeover\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 7.2 x 7.2 x 9 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley equipment is backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526432620735,"sku":"80-SWITCH-CHANGEOVER-63A","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/Manual-transfer-switch-1-phase.jpg?v=1790728212"},{"product_id":"welling-crossley-three-phase-4-pole-manual-transfer-switch","title":"Welling \u0026 Crossley Three Phase 4 Pole Manual Transfer Switch","description":"\u003cp\u003eA three phase, 4 pole manual transfer switch (changeover switch) from Welling \u0026amp; Crossley, available in 32, 63 and 100 amp ratings, for switching a site between mains and generator supply by hand.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree ratings:\u003c\/strong\u003e 32 A, 63 A and 100 A versions to match the generator and switchboard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 pole:\u003c\/strong\u003e switches all three phases and the neutral.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual changeover:\u003c\/strong\u003e the operator moves the site from mains to generator and back, with no automatic controls to configure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase:\u003c\/strong\u003e for three phase switchboards and generators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA changeover switch is the safe way to run a site from a generator: it isolates the mains before the generator supply is connected, so generator power cannot feed back into the grid. Never connect a generator to house wiring or a power point any other way. The switch connects into your switchboard, so installation is a job for a licensed electrician. Send us the generator model and we will confirm the right switch before you order.\u003c\/p\u003e\n\u003cp\u003eIt suits farms, workshops, factories and commercial premises with a three phase generator, where someone is on hand to switch over during an outage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your generator and switchboard details and the team will come back to you quickly.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModels:\u003c\/strong\u003e 80-SWITCH-C\/OVER-4P-032A (32A), 80-SWITCH-C\/OVER-4P-063A (63A), 80-SWITCH-C\/OVER-4P-100A (100A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Manual changeover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley equipment is backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526432686271,"sku":"80-SWITCH-C\/OVER-4P","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/Manual-transfer-switch-3-phase.jpg?v=1790728214"},{"product_id":"8kva-welling-crossley-honda-petrol-generator-wc-p8000h","title":"8kVA Welling \u0026 Crossley Honda Petrol Generator WC-P8000H","description":"\u003cp\u003eThe Welling \u0026amp; Crossley WC-P8000H is an 8kVA single phase petrol generator powered by a Euro 5 compliant Honda 4 stroke, air cooled OHV engine. It offers both recoil and electric start, CDI magneto ignition and low oil level shutdown.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHonda engine:\u003c\/strong\u003e 4 stroke, air cooled OHV, Euro 5 compliant, with a 3 year engine warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecoil and electric start:\u003c\/strong\u003e push-button starting with recoil as a backup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow oil level shutdown:\u003c\/strong\u003e stops the engine when oil runs low to protect it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCDI magneto ignition:\u003c\/strong\u003e electronic ignition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 x 15 Amp outlets:\u003c\/strong\u003e single phase outlets for tools and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit warranty:\u003c\/strong\u003e engine 3 years; alternator and frame 2 years (battery excluded).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePower is delivered through 2 x 15 Amp single phase outlets. Fuel tank, run time and noise figures are not published for this model.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eRated watts are not published for the WC-P8000H, so size your load conservatively. Each 15 Amp outlet supplies up to roughly 3600W at 240V (approximate). In a workshop that typically covers small to medium power tools and lighting; for home backup it typically covers essentials such as refrigeration, lights and internet. Motors draw a surge at start-up, so start the largest first. Check appliance plates and add up running watts before connecting.\u003c\/p\u003e\n\u003cp\u003eThe WC-P8000H suits DIY workshops, home backup for essential appliances, farm sheds, outdoor events and mobile businesses or market stalls. Home connection must be through an inlet and changeover switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e WC-P8000H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 8kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Honda, 4-stroke, air cooled, OHV, Euro 5 compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart type:\u003c\/strong\u003e Recoil and electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e CDI magneto\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlets:\u003c\/strong\u003e 2 x 15 Amp, single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Low oil level shutdown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Engine 3 years; alternator and frame 2 years (battery excluded)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 85 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 81 x 54.5 x 54.5 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526432719039,"sku":"WC-P8000H","price":3348.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/812773_WC-P8000H.jpg?v=1790728216"},{"product_id":"welling-crossley-automatic-transfer-switch-125a-to-1000a","title":"Welling \u0026 Crossley Automatic Transfer Switch, 125A to 1000A","description":"\u003cp\u003eWelling \u0026amp; Crossley automatic transfer switches keep a site running through a mains failure: the switch starts the generator over its 2-wire remote start connection, transfers the load and hands back once mains power returns. They are built in sizes from 125 amps to 1000 amps, in an IP66 rated enclosure.\u003c\/p\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003eDigital LCD display\u003c\/li\u003e\n\u003cli\u003eGenerator isolating handle\u003c\/li\u003e\n\u003cli\u003eAll necessary dual supply warning labels\u003c\/li\u003e\n\u003cli\u003eIP66 rated enclosure with padlock handle and double doors\u003c\/li\u003e\n\u003cli\u003eControl circuit breaker\u003c\/li\u003e\n\u003cli\u003e240V AC battery charger supply terminals\u003c\/li\u003e\n\u003cli\u003e2-wire remote start terminals\u003c\/li\u003e\n\u003cli\u003eGenerator isolating circuit breaker with shunt trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnattended changeover:\u003c\/strong\u003e starts the generator, transfers the load and hands back to mains without anyone on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-wire remote start:\u003c\/strong\u003e connects to generators with 2-wire remote start\/stop control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP66 enclosure:\u003c\/strong\u003e padlock handle and double doors for a secure, sealed installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator isolation:\u003c\/strong\u003e isolating handle and a generator isolating circuit breaker with shunt trip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery charger supply:\u003c\/strong\u003e 240 V AC terminals to keep the generator starting battery charged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e125 A to 1000 A:\u003c\/strong\u003e sized to the generator and switchboard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach switch is sized to the generator, the switchboard and the site, and installed by a licensed electrician. It suits farms, commercial premises, telecommunications and water infrastructure sites and any operation that cannot wait for someone to arrive and switch over by hand. Send us the generator model, phase and site details and we will quote the right switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Specification and delivery both move the number, so we quote each one properly. Use Add to Quote on this page and the team will come back to you.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eRating:\u003c\/strong\u003e 125A to 1000A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start:\u003c\/strong\u003e 2-wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e IP66 rated, padlock handle, double doors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley equipment is backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526432751807,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/ATS.jpg?v=1790728216"},{"product_id":"5-5kva-single-phase-welling-crossley-lister-petter-bore-pump-generator-llt5-5-1bpg","title":"5.5kVA Single Phase Welling \u0026 Crossley Lister Petter Bore Pump Generator LLT5.5\/1BPG","description":"\u003cp\u003eThe LLT5.5\/1BPG is a 5.5kVA single phase bore pump generator from Welling \u0026amp; Crossley, powered by a Lister Petter diesel engine. Bore pump generators match the engine to the alternator so the set can run an electric bore pump motor without light-loading the engine, and Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine:\u003c\/strong\u003e diesel power for a pump set, built by Welling \u0026amp; Crossley into one integrated power system with the alternator and controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine matched to alternator:\u003c\/strong\u003e sized so the set drives an electric bore pump motor without light-loading the engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated pump controller:\u003c\/strong\u003e Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together, rather than leaving the pump on a separate starter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase output:\u003c\/strong\u003e for single phase submersible and surface pump motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5.5kVA rating:\u003c\/strong\u003e a defined output for matching to the pump motor and its starting method.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuel tank capacity, fuel consumption and noise figures are not listed for this model, so ask us for them along with run time estimates for your pump and duty pattern. At 5.5kVA single phase, the set delivers up to approximately 22.9 A at 240 V (kVA x 1000 \/ 240).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eThe LLT5.5\/1BPG is built around one job: running an electric bore pump motor, typically with modest ancillary loads such as pump controls and site lighting within the 5.5kVA rating. Pump motors draw several times their running current as they start, so the set must be matched to the motor's kW rating and starting method (direct on line, soft starter or variable speed drive). Send us the pump model, motor rating, starter type and bore depth and we will confirm the match before you order. Check the motor rating plate rather than relying on the pump's nominal size.\u003c\/p\u003e\n\u003cp\u003eThe LLT5.5\/1BPG serves stations, farms and rural properties that rely on a bore for stock water, irrigation or household supply, as well as market gardens, nurseries and community water schemes where a dedicated pump generator is simpler than running cable to the bore head. Pairing the engine, alternator and pump controller as one set gives a single point of responsibility for the whole pumping system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLT5.5\/1BPG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 5.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Bore pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 300 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 100 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526433571007,"sku":"LLT5.5\/1BPG","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLT5-5-1BPG.jpg?v=1790728229"},{"product_id":"9kva-three-phase-welling-crossley-perkins-standby-diesel-generator-with-400l-tank-and-load-bank-ed9pye-3-400-lb","title":"9kVA Three Phase Welling \u0026 Crossley Perkins Standby Diesel Generator with 400L Tank and Load Bank ED9PYE\/3-400-LB","description":"\u003cp\u003eThe ED9PYE\/3-400-LB is a 9kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Perkins diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 400 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerkins diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400 litre fuel tank:\u003c\/strong\u003e a large on-board reserve for extended outages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in load bank:\u003c\/strong\u003e keeps the engine properly loaded during exercise runs and at light load, protecting a standby diesel from glazing and wet stacking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 400 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 9kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 9kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED9PYE\/3-400-LB suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED9PYE\/3-400-LB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 9kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Perkins diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 400 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad bank:\u003c\/strong\u003e Built in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1165 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 180 x 90 x 150 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526433702079,"sku":"ED9PYE\/3-400-LB","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD7.6-3C-400.jpg?v=1790728230"},{"product_id":"5-5kva-single-phase-welling-crossley-lister-petter-standby-diesel-generator-llt5-5-1","title":"5.5kVA Single Phase Welling \u0026 Crossley Lister Petter Standby Diesel Generator LLT5.5\/1","description":"\u003cp\u003eThe LLT5.5\/1 is a 5.5kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It carries a 90 litre fuel tank. The engine is air cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, air cooled:\u003c\/strong\u003e no radiator or coolant to maintain, paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 5.5kVA single phase, the set delivers up to approximately 22.9 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 5.5kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLT5.5\/1 suits standby duty at farms, workshops, small commercial premises and rural properties, installed in a plant room or shelter and wired to an ATS to take the load automatically when mains power fails. It is built for standby use and is not rated for prime or continuous duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLT5.5\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 5.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, air cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 300 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 100 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526433734847,"sku":"LLT5.5\/1","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLT5-5.jpg?v=1790728231"},{"product_id":"5-9kva-three-phase-welling-crossley-lister-petter-bore-pump-generator-llt5-9-3bpg","title":"5.9kVA Three Phase Welling \u0026 Crossley Lister Petter Bore Pump Generator LLT5.9\/3BPG","description":"\u003cp\u003eThe LLT5.9\/3BPG is a 5.9kVA three phase bore pump generator from Welling \u0026amp; Crossley, powered by a Lister Petter diesel engine. Bore pump generators match the engine to the alternator so the set can run an electric bore pump motor without light-loading the engine, and Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine:\u003c\/strong\u003e diesel power for a pump set, built by Welling \u0026amp; Crossley into one integrated power system with the alternator and controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine matched to alternator:\u003c\/strong\u003e sized so the set drives an electric bore pump motor without light-loading the engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated pump controller:\u003c\/strong\u003e Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together, rather than leaving the pump on a separate starter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase output:\u003c\/strong\u003e for three phase submersible and surface pump motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5.9kVA rating:\u003c\/strong\u003e a defined output for matching to the pump motor and its starting method.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuel tank capacity, fuel consumption and noise figures are not listed for this model, so ask us for them along with run time estimates for your pump and duty pattern. Its 5.9kVA output is delivered across three phases to suit a three phase pump starter.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eThe LLT5.9\/3BPG is built around one job: running an electric bore pump motor, typically with modest ancillary loads such as pump controls and site lighting within the 5.9kVA rating. Pump motors draw several times their running current as they start, so the set must be matched to the motor's kW rating and starting method (direct on line, soft starter or variable speed drive). Send us the pump model, motor rating, starter type and bore depth and we will confirm the match before you order. Check the motor rating plate rather than relying on the pump's nominal size.\u003c\/p\u003e\n\u003cp\u003eThe LLT5.9\/3BPG serves stations, farms and rural properties that rely on a bore for stock water, irrigation or household supply, as well as market gardens, nurseries and community water schemes where a dedicated pump generator is simpler than running cable to the bore head. Pairing the engine, alternator and pump controller as one set gives a single point of responsibility for the whole pumping system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLT5.9\/3BPG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 5.9kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Bore pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 300 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 100 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526433767615,"sku":"LLT5.9\/3BPG","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLT5-9-3BPG.jpg?v=1790728233"},{"product_id":"6-1kva-single-phase-welling-crossley-lister-petter-bore-pump-generator-lld6-1-1bpg","title":"6.1kVA Single Phase Welling \u0026 Crossley Lister Petter Bore Pump Generator LLD6.1\/1BPG","description":"\u003cp\u003eThe LLD6.1\/1BPG is a 6.1kVA single phase bore pump generator from Welling \u0026amp; Crossley, powered by a Lister Petter diesel engine. Bore pump generators match the engine to the alternator so the set can run an electric bore pump motor without light-loading the engine, and Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine:\u003c\/strong\u003e diesel power for a pump set, built by Welling \u0026amp; Crossley into one integrated power system with the alternator and controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine matched to alternator:\u003c\/strong\u003e sized so the set drives an electric bore pump motor without light-loading the engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated pump controller:\u003c\/strong\u003e Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together, rather than leaving the pump on a separate starter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase output:\u003c\/strong\u003e for single phase submersible and surface pump motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6.1kVA rating:\u003c\/strong\u003e a defined output for matching to the pump motor and its starting method.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuel tank capacity, fuel consumption and noise figures are not listed for this model, so ask us for them along with run time estimates for your pump and duty pattern. At 6.1kVA single phase, the set delivers up to approximately 25.4 A at 240 V (kVA x 1000 \/ 240).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eThe LLD6.1\/1BPG is built around one job: running an electric bore pump motor, typically with modest ancillary loads such as pump controls and site lighting within the 6.1kVA rating. Pump motors draw several times their running current as they start, so the set must be matched to the motor's kW rating and starting method (direct on line, soft starter or variable speed drive). Send us the pump model, motor rating, starter type and bore depth and we will confirm the match before you order. Check the motor rating plate rather than relying on the pump's nominal size.\u003c\/p\u003e\n\u003cp\u003eThe LLD6.1\/1BPG serves stations, farms and rural properties that rely on a bore for stock water, irrigation or household supply, as well as market gardens, nurseries and community water schemes where a dedicated pump generator is simpler than running cable to the bore head. Pairing the engine, alternator and pump controller as one set gives a single point of responsibility for the whole pumping system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD6.1\/1BPG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 6.1kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Bore pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 310 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526433800383,"sku":"LLD6.1\/1BPG","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD6-1-1BPG.jpg?v=1790728235"},{"product_id":"8-8kva-single-phase-welling-crossley-kubota-standby-diesel-generator-ed8-8kye","title":"8.8kVA Single Phase Welling \u0026 Crossley Kubota Standby Diesel Generator ED8.8KYE","description":"\u003cp\u003eThe ED8.8KYE is an 8.8kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 90 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 8.8kVA single phase, the set delivers up to approximately 36.7 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 8.8kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED8.8KYE suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED8.8KYE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 8.8kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 700 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 180 x 90 x 115.3 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434029759,"sku":"ED8.8KYE","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/DieselGenerator-90L_Kubota.jpg?v=1790728237"},{"product_id":"5-9kva-three-phase-welling-crossley-lister-petter-standby-diesel-generator-llt5-9-3","title":"5.9kVA Three Phase Welling \u0026 Crossley Lister Petter Standby Diesel Generator LLT5.9\/3","description":"\u003cp\u003eThe LLT5.9\/3 is a 5.9kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It carries a 90 litre fuel tank. The engine is air cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, air cooled:\u003c\/strong\u003e no radiator or coolant to maintain, paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 5.9kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 5.9kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLT5.9\/3 suits standby duty at farms, workshops, small commercial premises and rural properties, installed in a plant room or shelter and wired to an ATS to take the load automatically when mains power fails. It is built for standby use and is not rated for prime or continuous duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLT5.9\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 5.9kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, air cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 300 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 100 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434062527,"sku":"LLT5.9\/3","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLT6-1-3.jpg?v=1790728238"},{"product_id":"6-1kva-single-phase-welling-crossley-lister-petter-open-set-standby-diesel-generator-lld6-1-1","title":"6.1kVA Single Phase Welling \u0026 Crossley Lister Petter Open Set Standby Diesel Generator LLD6.1\/1","description":"\u003cp\u003eThe LLD6.1\/1 is a 6.1kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is supplied as an open set, ready to go into a plant room, container or custom enclosure, and carries a 90 litre fuel tank. The engine is water cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, water cooled:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen set:\u003c\/strong\u003e no enclosure, so it drops into an existing plant room, container or custom acoustic housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 6.1kVA single phase, the set delivers up to approximately 25.4 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 6.1kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLD6.1\/1 suits plant rooms in commercial buildings, factories and infrastructure sites, containerised power packages and custom acoustic enclosures, giving engineers and electrical contractors a Lister Petter and Crossley set to build into their own installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD6.1\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 6.1kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, water cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 310 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434095295,"sku":"LLD6.1\/1","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD6-1-3.jpg?v=1790728239"},{"product_id":"7-6kva-three-phase-welling-crossley-lister-petter-bore-pump-generator-lld7-6-3bpg","title":"7.6kVA Three Phase Welling \u0026 Crossley Lister Petter Bore Pump Generator LLD7.6\/3BPG","description":"\u003cp\u003eThe LLD7.6\/3BPG is a 7.6kVA three phase bore pump generator from Welling \u0026amp; Crossley, powered by a Lister Petter diesel engine. Bore pump generators match the engine to the alternator so the set can run an electric bore pump motor without light-loading the engine, and Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine:\u003c\/strong\u003e diesel power for a pump set, built by Welling \u0026amp; Crossley into one integrated power system with the alternator and controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine matched to alternator:\u003c\/strong\u003e sized so the set drives an electric bore pump motor without light-loading the engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated pump controller:\u003c\/strong\u003e Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together, rather than leaving the pump on a separate starter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase output:\u003c\/strong\u003e for three phase submersible and surface pump motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7.6kVA rating:\u003c\/strong\u003e a defined output for matching to the pump motor and its starting method.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuel tank capacity, fuel consumption and noise figures are not listed for this model, so ask us for them along with run time estimates for your pump and duty pattern. Its 7.6kVA output is delivered across three phases to suit a three phase pump starter.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eThe LLD7.6\/3BPG is built around one job: running an electric bore pump motor, typically with modest ancillary loads such as pump controls and site lighting within the 7.6kVA rating. Pump motors draw several times their running current as they start, so the set must be matched to the motor's kW rating and starting method (direct on line, soft starter or variable speed drive). Send us the pump model, motor rating, starter type and bore depth and we will confirm the match before you order. Check the motor rating plate rather than relying on the pump's nominal size.\u003c\/p\u003e\n\u003cp\u003eThe LLD7.6\/3BPG serves stations, farms and rural properties that rely on a bore for stock water, irrigation or household supply, as well as market gardens, nurseries and community water schemes where a dedicated pump generator is simpler than running cable to the bore head. Pairing the engine, alternator and pump controller as one set gives a single point of responsibility for the whole pumping system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD7.6\/3BPG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 7.6kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Bore pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 310 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434128063,"sku":"LLD7.6\/3BPG","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD7-6-3BPG.jpg?v=1790728241"},{"product_id":"9kva-three-phase-welling-crossley-kubota-standby-diesel-generator-ed9kye-3","title":"9kVA Three Phase Welling \u0026 Crossley Kubota Standby Diesel Generator ED9KYE\/3","description":"\u003cp\u003eThe ED9KYE\/3 is a 9kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 90 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 9kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 9kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED9KYE\/3 suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED9KYE\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 9kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 700 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 180 x 90 x 115.3 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434160831,"sku":"ED9KYE\/3","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/DieselGenerator-90L_Kubota_8c3c46c1-ea88-4d96-a321-7c36df8193bc.jpg?v=1790728242"},{"product_id":"7-6kva-three-phase-welling-crossley-lister-petter-open-set-standby-diesel-generator-lld7-6-3","title":"7.6kVA Three Phase Welling \u0026 Crossley Lister Petter Open Set Standby Diesel Generator LLD7.6\/3","description":"\u003cp\u003eThe LLD7.6\/3 is a 7.6kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is supplied as an open set, ready to go into a plant room, container or custom enclosure, and carries a 90 litre fuel tank. The engine is water cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, water cooled:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen set:\u003c\/strong\u003e no enclosure, so it drops into an existing plant room, container or custom acoustic housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 7.6kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 7.6kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLD7.6\/3 suits plant rooms in commercial buildings, factories and infrastructure sites, containerised power packages and custom acoustic enclosures, giving engineers and electrical contractors a Lister Petter and Crossley set to build into their own installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD7.6\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 7.6kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, water cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 310 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434193599,"sku":"LLD7.6\/3","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD7-6-3.jpg?v=1790728245"},{"product_id":"8-8kva-single-phase-welling-crossley-kubota-standby-diesel-generator-with-400l-tank-ed8-8kye-400","title":"8.8kVA Single Phase Welling \u0026 Crossley Kubota Standby Diesel Generator with 400L Tank ED8.8KYE-400","description":"\u003cp\u003eThe ED8.8KYE-400 is an 8.8kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 400 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400 litre fuel tank:\u003c\/strong\u003e a large on-board reserve for extended outages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 400 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 8.8kVA single phase, the set delivers up to approximately 36.7 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 8.8kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED8.8KYE-400 suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED8.8KYE-400\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 8.8kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 400 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1165 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 180 x 90 x 150 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434226367,"sku":"ED8.8KYE-400","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD7.6-3C-400_a5d445fd-f2b2-459f-a6fa-a77fec2ca7d1.jpg?v=1790728246"},{"product_id":"9-5kva-single-phase-welling-crossley-lister-petter-bore-pump-generator-lld9-5-1bpg","title":"9.5kVA Single Phase Welling \u0026 Crossley Lister Petter Bore Pump Generator LLD9.5\/1BPG","description":"\u003cp\u003eThe LLD9.5\/1BPG is a 9.5kVA single phase bore pump generator from Welling \u0026amp; Crossley, powered by a Lister Petter diesel engine. Bore pump generators match the engine to the alternator so the set can run an electric bore pump motor without light-loading the engine, and Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine:\u003c\/strong\u003e diesel power for a pump set, built by Welling \u0026amp; Crossley into one integrated power system with the alternator and controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine matched to alternator:\u003c\/strong\u003e sized so the set drives an electric bore pump motor without light-loading the engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated pump controller:\u003c\/strong\u003e Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together, rather than leaving the pump on a separate starter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase output:\u003c\/strong\u003e for single phase submersible and surface pump motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9.5kVA rating:\u003c\/strong\u003e a defined output for matching to the pump motor and its starting method.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuel tank capacity, fuel consumption and noise figures are not listed for this model, so ask us for them along with run time estimates for your pump and duty pattern. At 9.5kVA single phase, the set delivers up to approximately 39.6 A at 240 V (kVA x 1000 \/ 240).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eThe LLD9.5\/1BPG is built around one job: running an electric bore pump motor, typically with modest ancillary loads such as pump controls and site lighting within the 9.5kVA rating. Pump motors draw several times their running current as they start, so the set must be matched to the motor's kW rating and starting method (direct on line, soft starter or variable speed drive). Send us the pump model, motor rating, starter type and bore depth and we will confirm the match before you order. Check the motor rating plate rather than relying on the pump's nominal size.\u003c\/p\u003e\n\u003cp\u003eThe LLD9.5\/1BPG serves stations, farms and rural properties that rely on a bore for stock water, irrigation or household supply, as well as market gardens, nurseries and community water schemes where a dedicated pump generator is simpler than running cable to the bore head. Pairing the engine, alternator and pump controller as one set gives a single point of responsibility for the whole pumping system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD9.5\/1BPG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 9.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Bore pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 380 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434259135,"sku":"LLD9.5\/1BPG","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD9-5-1BPG.jpg?v=1790728248"},{"product_id":"9kva-three-phase-welling-crossley-kubota-standby-diesel-generator-with-400l-tank-ed9kye-3-400","title":"9kVA Three Phase Welling \u0026 Crossley Kubota Standby Diesel Generator with 400L Tank ED9KYE\/3-400","description":"\u003cp\u003eThe ED9KYE\/3-400 is a 9kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 400 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400 litre fuel tank:\u003c\/strong\u003e a large on-board reserve for extended outages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 400 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 9kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 9kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED9KYE\/3-400 suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED9KYE\/3-400\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 9kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 400 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1165 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 180 x 90 x 150 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434291903,"sku":"ED9KYE\/3-400","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD7.6-3C-400_56bccda2-d102-4340-884f-a9769eabfbd0.jpg?v=1790728249"},{"product_id":"9-5kva-single-phase-welling-crossley-lister-petter-open-set-standby-diesel-generator-lld9-5-1","title":"9.5kVA Single Phase Welling \u0026 Crossley Lister Petter Open Set Standby Diesel Generator LLD9.5\/1","description":"\u003cp\u003eThe LLD9.5\/1 is a 9.5kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is supplied as an open set, ready to go into a plant room, container or custom enclosure, and carries a 90 litre fuel tank. The engine is water cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, water cooled:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen set:\u003c\/strong\u003e no enclosure, so it drops into an existing plant room, container or custom acoustic housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 9.5kVA single phase, the set delivers up to approximately 39.6 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 9.5kVA it typically covers the essential circuits of a home, small business or rural property: refrigeration and freezers, lighting, a water pump, IT and communications gear and a few workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLD9.5\/1 suits plant rooms in commercial buildings, factories and infrastructure sites, containerised power packages and custom acoustic enclosures, giving engineers and electrical contractors a Lister Petter and Crossley set to build into their own installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD9.5\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 9.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, water cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 380 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434685119,"sku":"LLD9.5\/1","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD9-5-1.jpg?v=1790728251"},{"product_id":"10-5kva-single-phase-welling-crossley-kubota-standby-diesel-generator-ed10-5kye","title":"10.5kVA Single Phase Welling \u0026 Crossley Kubota Standby Diesel Generator ED10.5KYE","description":"\u003cp\u003eThe ED10.5KYE is a 10.5kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 90 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 10.5kVA single phase, the set delivers up to approximately 43.8 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 10.5kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED10.5KYE suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED10.5KYE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 10.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 770 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 200 x 90 x 115.3 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434750655,"sku":"ED10.5KYE","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/DieselGenerator-90L_Kubota_5ebc8f60-b110-473b-81f1-65eb76db4155.jpg?v=1790728253"},{"product_id":"12kva-single-phase-welling-crossley-lister-petter-bore-pump-generator-llt12-1bpg","title":"12kVA Single Phase Welling \u0026 Crossley Lister Petter Bore Pump Generator LLT12\/1BPG","description":"\u003cp\u003eThe LLT12\/1BPG is a 12kVA single phase bore pump generator from Welling \u0026amp; Crossley, powered by a Lister Petter diesel engine. Bore pump generators match the engine to the alternator so the set can run an electric bore pump motor without light-loading the engine, and Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine:\u003c\/strong\u003e diesel power for a pump set, built by Welling \u0026amp; Crossley into one integrated power system with the alternator and controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine matched to alternator:\u003c\/strong\u003e sized so the set drives an electric bore pump motor without light-loading the engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated pump controller:\u003c\/strong\u003e Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together, rather than leaving the pump on a separate starter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase output:\u003c\/strong\u003e for single phase submersible and surface pump motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12kVA rating:\u003c\/strong\u003e a defined output for matching to the pump motor and its starting method.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuel tank capacity, fuel consumption and noise figures are not listed for this model, so ask us for them along with run time estimates for your pump and duty pattern. At 12kVA single phase, the set delivers up to approximately 50 A at 240 V (kVA x 1000 \/ 240).\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eThe LLT12\/1BPG is built around one job: running an electric bore pump motor, typically with modest ancillary loads such as pump controls and site lighting within the 12kVA rating. Pump motors draw several times their running current as they start, so the set must be matched to the motor's kW rating and starting method (direct on line, soft starter or variable speed drive). Send us the pump model, motor rating, starter type and bore depth and we will confirm the match before you order. Check the motor rating plate rather than relying on the pump's nominal size.\u003c\/p\u003e\n\u003cp\u003eThe LLT12\/1BPG serves stations, farms and rural properties that rely on a bore for stock water, irrigation or household supply, as well as market gardens, nurseries and community water schemes where a dedicated pump generator is simpler than running cable to the bore head. Pairing the engine, alternator and pump controller as one set gives a single point of responsibility for the whole pumping system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLT12\/1BPG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 12kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Bore pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 430 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434783423,"sku":"LLT12\/1BPG","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLT12-1BPG.jpg?v=1790728254"},{"product_id":"12kva-three-phase-welling-crossley-lister-petter-bore-pump-generator-lld12-3bpg","title":"12kVA Three Phase Welling \u0026 Crossley Lister Petter Bore Pump Generator LLD12\/3BPG","description":"\u003cp\u003eThe LLD12\/3BPG is a 12kVA three phase bore pump generator from Welling \u0026amp; Crossley, powered by a Lister Petter diesel engine. Bore pump generators match the engine to the alternator so the set can run an electric bore pump motor without light-loading the engine, and Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine:\u003c\/strong\u003e diesel power for a pump set, built by Welling \u0026amp; Crossley into one integrated power system with the alternator and controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine matched to alternator:\u003c\/strong\u003e sized so the set drives an electric bore pump motor without light-loading the engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated pump controller:\u003c\/strong\u003e Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together, rather than leaving the pump on a separate starter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase output:\u003c\/strong\u003e for three phase submersible and surface pump motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12kVA rating:\u003c\/strong\u003e a defined output for matching to the pump motor and its starting method.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuel tank capacity, fuel consumption and noise figures are not listed for this model, so ask us for them along with run time estimates for your pump and duty pattern. Its 12kVA output is delivered across three phases to suit a three phase pump starter.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eThe LLD12\/3BPG is built around one job: running an electric bore pump motor, typically with modest ancillary loads such as pump controls and site lighting within the 12kVA rating. Pump motors draw several times their running current as they start, so the set must be matched to the motor's kW rating and starting method (direct on line, soft starter or variable speed drive). Send us the pump model, motor rating, starter type and bore depth and we will confirm the match before you order. Check the motor rating plate rather than relying on the pump's nominal size.\u003c\/p\u003e\n\u003cp\u003eThe LLD12\/3BPG serves stations, farms and rural properties that rely on a bore for stock water, irrigation or household supply, as well as market gardens, nurseries and community water schemes where a dedicated pump generator is simpler than running cable to the bore head. Pairing the engine, alternator and pump controller as one set gives a single point of responsibility for the whole pumping system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD12\/3BPG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 12kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Bore pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 380 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434816191,"sku":"LLD12\/3BPG","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD12-3BPG.jpg?v=1790728256"},{"product_id":"12kva-three-phase-welling-crossley-lister-petter-open-set-standby-diesel-generator-lld12-3","title":"12kVA Three Phase Welling \u0026 Crossley Lister Petter Open Set Standby Diesel Generator LLD12\/3","description":"\u003cp\u003eThe LLD12\/3 is a 12kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is supplied as an open set, ready to go into a plant room, container or custom enclosure, and carries a 90 litre fuel tank. The engine is water cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, water cooled:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen set:\u003c\/strong\u003e no enclosure, so it drops into an existing plant room, container or custom acoustic housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 12kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 12kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLD12\/3 suits plant rooms in commercial buildings, factories and infrastructure sites, containerised power packages and custom acoustic enclosures, giving engineers and electrical contractors a Lister Petter and Crossley set to build into their own installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD12\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 12kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, water cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 380 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434848959,"sku":"LLD12\/3","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD12-3.jpg?v=1790728257"},{"product_id":"10-5kva-single-phase-welling-crossley-kubota-standby-diesel-generator-with-400l-tank-and-load-bank-ed10-5kye-400-lb","title":"10.5kVA Single Phase Welling \u0026 Crossley Kubota Standby Diesel Generator with 400L Tank and Load Bank ED10.5KYE-400-LB","description":"\u003cp\u003eThe ED10.5KYE-400-LB is a 10.5kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 400 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400 litre fuel tank:\u003c\/strong\u003e a large on-board reserve for extended outages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in load bank:\u003c\/strong\u003e keeps the engine properly loaded during exercise runs and at light load, protecting a standby diesel from glazing and wet stacking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 400 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 10.5kVA single phase, the set delivers up to approximately 43.8 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 10.5kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED10.5KYE-400-LB suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED10.5KYE-400-LB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 10.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 400 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad bank:\u003c\/strong\u003e Built in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1080 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 215 x 95 x 155 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434914495,"sku":"ED10.5KYE-400-LB","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/DieselGenerator-LoadBanks.jpg?v=1790728260"},{"product_id":"12-1kva-single-phase-welling-crossley-lister-petter-standby-diesel-generator-llt12-1-1","title":"12.1kVA Single Phase Welling \u0026 Crossley Lister Petter Standby Diesel Generator LLT12.1\/1","description":"\u003cp\u003eThe LLT12.1\/1 is a 12.1kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It carries a 90 litre fuel tank. The engine is air cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, air cooled:\u003c\/strong\u003e no radiator or coolant to maintain, paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 12.1kVA single phase, the set delivers up to approximately 50.4 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 12.1kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLT12.1\/1 suits standby duty at farms, workshops, small commercial premises and rural properties, installed in a plant room or shelter and wired to an ATS to take the load automatically when mains power fails. It is built for standby use and is not rated for prime or continuous duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLT12.1\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 12.1kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, air cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 430 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526434947263,"sku":"LLT12.1\/1","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLT12-1-1.jpg?v=1790728261"},{"product_id":"12kva-three-phase-welling-crossley-kubota-standby-diesel-generator-ed12kye-3","title":"12kVA Three Phase Welling \u0026 Crossley Kubota Standby Diesel Generator ED12KYE\/3","description":"\u003cp\u003eThe ED12KYE\/3 is a 12kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 90 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 12kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 12kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED12KYE\/3 suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED12KYE\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 12kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 770 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 200 x 90 x 115.3 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526435078335,"sku":"ED12KYE\/3","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/DieselGenerator-90L_Kubota_655749b7-d34f-4094-8a00-07b8cd9258ca.jpg?v=1790728266"},{"product_id":"13-5kva-single-phase-welling-crossley-lister-petter-open-set-standby-diesel-generator-lld13-5-1","title":"13.5kVA Single Phase Welling \u0026 Crossley Lister Petter Open Set Standby Diesel Generator LLD13.5\/1","description":"\u003cp\u003eThe LLD13.5\/1 is a 13.5kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is supplied as an open set, ready to go into a plant room, container or custom enclosure, and carries a 90 litre fuel tank. The engine is water cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, water cooled:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen set:\u003c\/strong\u003e no enclosure, so it drops into an existing plant room, container or custom acoustic housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 13.5kVA single phase, the set delivers up to approximately 56.2 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 13.5kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLD13.5\/1 suits plant rooms in commercial buildings, factories and infrastructure sites, containerised power packages and custom acoustic enclosures, giving engineers and electrical contractors a Lister Petter and Crossley set to build into their own installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD13.5\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 13.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, water cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 430 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526435307711,"sku":"LLD13.5\/1","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD13-5-3.jpg?v=1790728268"},{"product_id":"15kva-three-phase-welling-crossley-lister-petter-standby-diesel-generator-llt15-3","title":"15kVA Three Phase Welling \u0026 Crossley Lister Petter Standby Diesel Generator LLT15\/3","description":"\u003cp\u003eThe LLT15\/3 is a 15kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It carries a 90 litre fuel tank. The engine is air cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, air cooled:\u003c\/strong\u003e no radiator or coolant to maintain, paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 15kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 15kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLT15\/3 suits standby duty at farms, workshops, small commercial premises and rural properties, installed in a plant room or shelter and wired to an ATS to take the load automatically when mains power fails. It is built for standby use and is not rated for prime or continuous duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLT15\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 15kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, air cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 430 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526435471551,"sku":"LLT15\/3","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLT15-3.jpg?v=1790728272"},{"product_id":"15kva-three-phase-welling-crossley-lister-petter-bore-pump-generator-llt15-3bpg","title":"15kVA Three Phase Welling \u0026 Crossley Lister Petter Bore Pump Generator LLT15\/3BPG","description":"\u003cp\u003eThe LLT15\/3BPG is a 15kVA three phase bore pump generator from Welling \u0026amp; Crossley, powered by a Lister Petter diesel engine. Bore pump generators match the engine to the alternator so the set can run an electric bore pump motor without light-loading the engine, and Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine:\u003c\/strong\u003e diesel power for a pump set, built by Welling \u0026amp; Crossley into one integrated power system with the alternator and controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine matched to alternator:\u003c\/strong\u003e sized so the set drives an electric bore pump motor without light-loading the engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated pump controller:\u003c\/strong\u003e Welling \u0026amp; Crossley's own controller monitors and protects the engine, alternator and pump together, rather than leaving the pump on a separate starter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase output:\u003c\/strong\u003e for three phase submersible and surface pump motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15kVA rating:\u003c\/strong\u003e a defined output for matching to the pump motor and its starting method.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFuel tank capacity, fuel consumption and noise figures are not listed for this model, so ask us for them along with run time estimates for your pump and duty pattern. Its 15kVA output is delivered across three phases to suit a three phase pump starter.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eThe LLT15\/3BPG is built around one job: running an electric bore pump motor, typically with modest ancillary loads such as pump controls and site lighting within the 15kVA rating. Pump motors draw several times their running current as they start, so the set must be matched to the motor's kW rating and starting method (direct on line, soft starter or variable speed drive). Send us the pump model, motor rating, starter type and bore depth and we will confirm the match before you order. Check the motor rating plate rather than relying on the pump's nominal size.\u003c\/p\u003e\n\u003cp\u003eThe LLT15\/3BPG serves stations, farms and rural properties that rely on a bore for stock water, irrigation or household supply, as well as market gardens, nurseries and community water schemes where a dedicated pump generator is simpler than running cable to the bore head. Pairing the engine, alternator and pump controller as one set gives a single point of responsibility for the whole pumping system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLT15\/3BPG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 15kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Bore pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 430 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526435504319,"sku":"LLT15\/3BPG","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLT15-3BPG.jpg?v=1790728274"},{"product_id":"12kva-three-phase-welling-crossley-kubota-standby-diesel-generator-with-400l-tank-and-load-bank-ed12kye-3-400-lb","title":"12kVA Three Phase Welling \u0026 Crossley Kubota Standby Diesel Generator with 400L Tank and Load Bank ED12KYE\/3-400-LB","description":"\u003cp\u003eThe ED12KYE\/3-400-LB is a 12kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 400 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400 litre fuel tank:\u003c\/strong\u003e a large on-board reserve for extended outages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in load bank:\u003c\/strong\u003e keeps the engine properly loaded during exercise runs and at light load, protecting a standby diesel from glazing and wet stacking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 400 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 12kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 12kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED12KYE\/3-400-LB suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED12KYE\/3-400-LB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 12kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 400 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad bank:\u003c\/strong\u003e Built in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1080 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 215 x 95 x 155 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526440419519,"sku":"ED12KYE\/3-400-LB","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/DieselGenerator-LoadBanks_9d59d23a-250c-4eea-93e7-93415f58f213.jpg?v=1790728276"},{"product_id":"14-5kva-single-phase-welling-crossley-kubota-standby-diesel-generator-ed14-5kye","title":"14.5kVA Single Phase Welling \u0026 Crossley Kubota Standby Diesel Generator ED14.5KYE","description":"\u003cp\u003eThe ED14.5KYE is a 14.5kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 90 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 14.5kVA single phase, the set delivers up to approximately 60.4 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 14.5kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED14.5KYE suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED14.5KYE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 14.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 990 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 200 x 90 x 115.3 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526440452287,"sku":"ED14.5KYE","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/DieselGenerator-90L_Kubota_ea3628b6-ada9-40f3-8f18-8d8b893ff830.jpg?v=1790728277"},{"product_id":"16-5kva-three-phase-welling-crossley-lister-petter-open-set-standby-diesel-generator-lld16-5-3","title":"16.5kVA Three Phase Welling \u0026 Crossley Lister Petter Open Set Standby Diesel Generator LLD16.5\/3","description":"\u003cp\u003eThe LLD16.5\/3 is a 16.5kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is supplied as an open set, ready to go into a plant room, container or custom enclosure, and carries a 90 litre fuel tank. The engine is water cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, water cooled:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen set:\u003c\/strong\u003e no enclosure, so it drops into an existing plant room, container or custom acoustic housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 16.5kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 16.5kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLD16.5\/3 suits plant rooms in commercial buildings, factories and infrastructure sites, containerised power packages and custom acoustic enclosures, giving engineers and electrical contractors a Lister Petter and Crossley set to build into their own installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD16.5\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 16.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, water cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 430 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526440485055,"sku":"LLD16.5\/3","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD16-5-3-1.jpg?v=1790728279"},{"product_id":"14-5kva-three-phase-welling-crossley-kubota-standby-diesel-generator-ed14-5kye-3","title":"14.5kVA Three Phase Welling \u0026 Crossley Kubota Standby Diesel Generator ED14.5KYE\/3","description":"\u003cp\u003eThe ED14.5KYE\/3 is a 14.5kVA three phase standby diesel generator from Welling \u0026amp; Crossley, built around a Kubota diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is housed in a weather protective acoustic canopy and carries a 90 litre fuel tank. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota diesel engine:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather protective acoustic canopy:\u003c\/strong\u003e housed for outdoor installation on a slab, with acoustic treatment to reduce noise at the site boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. Its 14.5kVA output is delivered across three phases for three phase distribution boards and motors. Output connects into your switchboard through a transfer switch installed by a licensed electrician. If your site has a noise limit, ask us for the acoustic data, as no measured figure is listed.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 14.5kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a three phase set it runs three phase motors and machinery directly, and single phase loads should be spread evenly across the three phases. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe ED14.5KYE\/3 suits standby duty at farms, workshops, commercial premises, telecommunications and water infrastructure sites, and any operation where an outage costs money: installed outdoors in its canopy and wired to an ATS, it waits for a mains failure and takes the load automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ED14.5KYE\/3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 14.5kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Kubota diesel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Weather protective acoustic canopy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 990 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 200 x 90 x 115.3 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526440878271,"sku":"ED14.5KYE\/3","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/DieselGenerator-90L_Kubota_8817898f-b06c-48a9-85a7-6478f51daf62.jpg?v=1790728280"},{"product_id":"17-7kva-single-phase-welling-crossley-lister-petter-open-set-standby-diesel-generator-lld17-7-1","title":"17.7kVA Single Phase Welling \u0026 Crossley Lister Petter Open Set Standby Diesel Generator LLD17.7\/1","description":"\u003cp\u003eThe LLD17.7\/1 is a 17.7kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It is supplied as an open set, ready to go into a plant room, container or custom enclosure, and carries a 90 litre fuel tank. The engine is water cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, water cooled:\u003c\/strong\u003e paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen set:\u003c\/strong\u003e no enclosure, so it drops into an existing plant room, container or custom acoustic housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 17.7kVA single phase, the set delivers up to approximately 73.8 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 17.7kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLD17.7\/1 suits plant rooms in commercial buildings, factories and infrastructure sites, containerised power packages and custom acoustic enclosures, giving engineers and electrical contractors a Lister Petter and Crossley set to build into their own installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLD17.7\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 17.7kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, water cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open set\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 520 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526440911039,"sku":"LLD17.7\/1","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLD17-7-1.jpg?v=1790728282"},{"product_id":"18kva-single-phase-welling-crossley-lister-petter-standby-diesel-generator-llt18-1","title":"18kVA Single Phase Welling \u0026 Crossley Lister Petter Standby Diesel Generator LLT18\/1","description":"\u003cp\u003eThe LLT18\/1 is an 18kVA single phase standby diesel generator from Welling \u0026amp; Crossley, built around a Lister Petter diesel engine and a Crossley SLG series single bearing, 4-pole brushless alternator. It carries a 90 litre fuel tank. The engine is air cooled. Remote start\/stop control lets it be wired to an automatic transfer switch (ATS) to start, take the load and stand down again with nobody on site.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLister Petter diesel engine, air cooled:\u003c\/strong\u003e no radiator or coolant to maintain, paired with the Crossley alternator as a complete generating set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrushless 4-pole alternator:\u003c\/strong\u003e no brushes to wear or replace, and a 4-pole design for steady, lower speed running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle bearing build:\u003c\/strong\u003e the alternator couples directly to the engine, a compact and simple drive arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote start\/stop:\u003c\/strong\u003e ready to pair with an automatic transfer switch for unattended changeover when mains power fails and back again when it returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 litre fuel tank:\u003c\/strong\u003e on-board fuel for standby running.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRun time from the 90 litre tank depends on load; consumption figures are not listed for this model, so ask us for them at your expected load. At 18kVA single phase, the set delivers up to approximately 75 A at 240 V (kVA x 1000 \/ 240). Output connects into your switchboard through a transfer switch installed by a licensed electrician.\u003c\/p\u003e\n\u003ch3\u003eWhat it will run\u003c\/h3\u003e\n\u003cp\u003eAt 18kVA it typically suits a rural property, small business or workshop: refrigeration and coolroom equipment, lighting, bore or transfer pumps, office and communications gear and workshop tools, run together within the rating. As a single phase set it suits single phase switchboards and equipment; it will not run three phase motors. Motors (pumps, compressors, coolroom and air conditioning units) draw several times their running current as they start, so allow headroom for the largest one, check appliance rating plates, and size on what must keep running during an outage.\u003c\/p\u003e\n\u003cp\u003eThe LLT18\/1 suits standby duty at farms, workshops, small commercial premises and rural properties, installed in a plant room or shelter and wired to an ATS to take the load automatically when mains power fails. It is built for standby use and is not rated for prime or continuous duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Use Add to Quote on this page with your load and site details and the team will come back to you with a price and lead time.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-position: outside; padding-left: 1.5em; margin-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e LLT18\/1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output:\u003c\/strong\u003e 18kVA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngine:\u003c\/strong\u003e Lister Petter diesel, air cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternator:\u003c\/strong\u003e Crossley SLG series, single bearing, 4-pole, brushless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e Remote start\/stop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel tank:\u003c\/strong\u003e 90 litres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 480 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H):\u003c\/strong\u003e 140 x 76 x 120 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWelling \u0026amp; Crossley generators are backed Australia-wide with national parts and service support.\u003c\/p\u003e","brand":"Welling \u0026 Crossley","offers":[{"title":"Default Title","offer_id":67526440943807,"sku":"LLT18\/1","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/files\/LLT18-1.jpg?v=1790728283"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7409\/5295\/collections\/811987.jpg?v=1789276731","url":"https:\/\/gen4sale.com.au\/collections\/welling-crossley.oembed?page=3","provider":"Gen4Sale","version":"1.0","type":"link"}